Reason 2:
Penalty lockout following three incorrect password attempts.
Solution: Press
Esc
+1+2 to reset the multiplexer, then input the password
again.
Symptom: Front panel keys are not working.
Reason:
Front panel keys are locked.
Solution: Press
Esc
and
Lock
key together to unlock the front panel.
Symptom: When more than one remote keypad is connected, the remote keypad does not work properly.
Reason:
Remote control keypad IN/OUT connectors were not connected
properly.
Solution: Please
refer
Appendix D: Remote Control Panel User’s Guide
page 62 for the correct connection method.
Remote Control Panel
Symptom: The channel LEDs always light one by one
Reason 1:
Connecting cables may be loose or improperly installed.
Solution:
Make sure that the RS-485 cables are properly connected.
Reason 2:
Multiplexer may be assigned an incorrect RS-485 address.
Solution
Assign the multiplexer a RS-485 ID address between 224
and 239. (See
Reason 3:
Transmission baud rate incompatible with cable rating.
Solution
Set baud rate to factory default setting. (9600 baud). See
on page 46 for more information
.
Remote control panel LEDs light at random OR the LED status display does not correspond to multiplexer’s status
Reason:
More than one multiplexer has the same RS-485 ID
address.
Solution:
Verify that all multiplexers have a unique RS-485 ID
address. (Refer to
Содержание Multivision Quest TMV910Q
Страница 3: ...Triplex Digital Video Multiplexer User s Guide...
Страница 8: ...User s Guide vi User s Guide Alarm 69 Keypad and Password 69 Remote Control Panel 70...
Страница 12: ...User s Guide 4 Technical Overview NOTES...
Страница 18: ...User s Guide 10 System Installation NOTES...
Страница 30: ...User s Guide 22 Basic Operations NOTES...
Страница 60: ...User s Guide 52 Advanced Setup Using On Screen Menus NOTES...
Страница 62: ...User s Guide 54 Maintenance NOTES...