40
ADCC1100
Configuring for MP48, AD1024 or Quicksite Mode
The ADCC1100 keyboard is designed for use with the MP48 or AD1024 matrix switch-
ing system. The ADCC1100 keyboard needs to be set to one of these systems in order
to operate correctly.
Quicksite mode should be used to support systems with multiple AD1024 matrix sites
where switching between satellite sites has been configured to take place automati-
cally. For example, a system with three distinct satellite sites can be created, each with
its own video inputs, video outputs and keyboards. Once trunk connections have been
made between the satellite sites, a keyboard from one site can be used to call video
inputs from another site, without having to select the site first. All the operator needs to
do is enter the pseudo number of the required video input. Refer to the AD1024
Satellite Configuration Installation Instructions for details on how AD1024 matrices can
be configured for this functionality.
AD1024 mode should be used to support single AD1024 switching matrices or systems
with multiple AD1024 sites where satellite site selection is to carried out manually. This
mode also supports the AD2150 switching matrix. MP48 mode should be used to
support the MP48, MP48+, AD168, MP168 and AD MP-LT matrix systems.
1. Using the Administrator's smart card, log on to the system.
2. Press the PROGRAM MODE tab key.
3. Press the NEXT soft key.
4. Press the MP48 MODE/AD1024 MODE/QUICKSITE MODE soft key. This has a
toggle action selecting MP48 Mode, AD1024 Mode or Quicksite Mode.
5. Remove the Administrator's smart card.
The keyboard is now set to the selected mode and will retain this settingeven after
powering off the keyboarduntil it is changed again using the steps above.
Note
: See the section
Quicksite Configuration
below for details on specifying camera
pseudo numbers in the Quicksite configuration menu.
Quicksite Configuration
When Quicksite mode has been selected as the mode of operation for the matrix (see
above), an operator with administrator privileges can use an ADCC100 keyboard to
configure Quicksite settings.
To open the Quicksite configuration menu:
1. Press the PROGRAM MODE tab key.
2. Press the NEXT soft key.
3. Ensure that the MP48 MODE/AD1024 MODE/QUICKSITE MODE soft key is set
to Quicksite mode.
4. Press the PARTITION QUICKSITE soft key. The partition menu will be displayed
(figure 4.6), but an extra soft key is added to the bottom right of the screen.
All manuals and user guides at all-guides.com
all-guides.com