background image

(1) Supported by SpeedDome Ultra VII or SpeedDome Ultra 8.
(2) Some digital video recorders, video servers, or similar products may lose color information when UTP cable distances exceed 180 m (600 ft).

Alarm Clearance Methods

•  Acknowledge:

 Alarms must be manually acknowledged.

•   Time Out:

 Alarms are automatically cleared after a  

pre-defined dwell time of 2 to 99 seconds. Alarms can also 
be manually acknowledged.

•   Transparent:

 Alarms are cleared after the alarm contact 

returns to its neutral state. If the contact returns to this state 
before the transparent dwell time of 2 to 99 seconds, then 
the alarm remains active for that predefined period. Alarms 
can also be manually acknowledged.

events

An event is a message that is passed from one matrix to 
itself or other matrix systems (up to 3 on an ADnet network). 
Up to 255 events can be defined and each system can have 
a predefined event response. In addition, events can be 
generated from any ControlCenter 200 or 300 keyboard to 
produce a system response.

system Partitioning

Defining authorized access to keyboards, video inputs and 
video outputs further enhances system flexibility. System 
partitioning includes the following:

•   Keyboard-to-Monitor Access:

 Restricts selected  

keyboards from accessing selected video outputs.

•   Keyboard-to-Camera Access:

 Restricts selected  

keyboards from calling or controlling selected video inputs.

•   Keyboard-to-Camera Control Access:

 Allows selected 

keyboards to view certain cameras but restricts those  
keyboards from controlling the cameras.

Keyboard Priority Operation

Keyboards can be assigned one of 8 levels of priority control 
of remote camera sites. Level 1 has highest priority for 
control of cameras. Up to 4 keyboards may simultaneously 
control PTZ devices.

Model Numbers

ADMPLT16 . . . . . . . . . . . .  MegaPower LT, 16 inputs x 4 outputs, 

(120/230 VAC, NTSC/PAL)

ADMPLT16C2 . . . . . . . . . .  MegaPower LT, 16 inputs x 4 outputs, 

(120/230 VAC, NTSC/PAL) with 

ControlCenter 200 keyboard

ADMPLT16C3 . . . . . . . . . .  MegaPower LT, 16 inputs x 4 outputs, 

(120/230 VAC, NTSC/PAL) with 

ControlCenter 300 keyboard

ADMPLT32 . . . . . . . . . . . .  MegaPower LT, 32 inputs x 8 outputs, 

(120/230 VAC, NTSC/PAL)

ADMPLT32C2 . . . . . . . . . .  MegaPower LT, 32 inputs x 8 outputs, 

(120/230 VAC, NTSC/PAL) with 

ControlCenter 200 keyboard

ADMPLT32C3 . . . . . . . . . .  MegaPower LT, 32 inputs x 8 outputs, 

(120/230 VAC, NTSC/PAL) with 

ControlCenter 300 keyboard

Directset

1

Allows the operator to quickly access and change dome 
camera settings either via an on-screen selection or simple 
keyboard command, without the need to access the dome 
menus. Features like wide dynamic range, day/night and 
dome information screens can be easily accessed without 
compromising other dome settings.

Dome Ping

This utility allows the administrator to verify the integrity of 
the communication between the matrix and the dome on 
both SensorNet and the AD-UTC protocol.

Internal Video Loss Detection

Video loss detection is standard on all video inputs. If such 
a camera is selected, a red screen will appear with a “Video 
Loss Camera” message.

On-Board Diagnostics

Built-in diagnostics allow the user to determine the status of 
the system’s internal components. LEDs on the front of the 
unit clearly indicate power status and system health.

Optional Accessories

Accessory

Description

ADCC0200, 

ADCC0300 

ControlCenter 

Keyboards

Full system keyboards allow for video switching,  

pan/tilt control, dome control, auxiliary control, 

recorder control, multiplexer control and system 

programming. The keyboards support bi-directional 

communication with the matrix via ADnet.

ADCC1100  

MegaPower  

ControlCenter 

Keyboard

Full system, smart card enabled keyboards allow 

for video switching, pan/tilt control, dome control, 

auxiliary control, macro control, user partitioning and 

access, recorder control and system programming. 

The keyboards support bi-directional communication 

with the CPU via RS-232 ASCII commands.

ADTTE Touch Tracker 

Keyboard

Full system keyboards allow for video switching, pan/

tilt control, dome control, auxiliary control and system 

programming. The keyboards support bi-directional 

communication with the CPU via RS-232 ASCII.

AD2088 and AD2089  

Keyboards

Full system keyboards allow for video switching, pan/

tilt control, dome control, auxiliary control, macro 

control, recorder control, and system programming. 

The keyboards support bi-directional communication 

with the CPU via RS-232 ASCII commands.

AD2081, AD2081-1  

Port Expander

Expands one RS-232 port on a system into 4 ports. 

This provides connections to multiple system  

keyboards.

RCSN422, SensorNet-

to-RS-422 Converter

Control of RS-422 domes using the RCSN422  

SensorNet-to-RS-422 converter.

ADACTP01BNC  

Twisted Pair Video 

Adapter

A passive transmission device that transmits video 

or video with Up-The-Cable (AD-UTC) dome control 

signals over Unshielded Twisted Pair (UTP) cables, 

point-to-point, for distances up to 300 m (1,000 ft)

2

These adapters use Category 2-6 twisted pair wires 

to transmit the video and dome control signals  

and do not require power.

VRCMKIT Cable 

Brackets

Each kit contains 3 cable management brackets.

Содержание ADMPLT16

Страница 1: ...igh end system including partitioning priorities sequences and includes a robust alarm handling package In addition you can network up to three MegaPower LT systems to form a distributed system MegaPower LT is also easily integrated with other security system components through the American Dynamics standard RS 232 keyboard protocol MegaPower LT Matrix Switcher Controller System Features That Make...

Страница 2: ...boards to support different command sets Time and Date Administrators can set the display to a 12 or 24 hour clock Three date formats are provided MM DD YY YY MM DD DD MM YY In addition the daylight savings time option enables the clock to be adjusted forward backward or no action Views Program up to 128 views each with a camera input number and either a preset number or a pattern number Each view...

Страница 3: ...n selection or simple keyboard command without the need to access the dome menus Features like wide dynamic range day night and dome information screens can be easily accessed without compromising other dome settings Dome Ping This utility allows the administrator to verify the integrity of the communication between the matrix and the dome on both SensorNet and the AD UTC protocol Internal Video L...

Страница 4: ...through 5 pin pluggable Eurostyle terminal screw connectors Alarm Inputs 4 Connectors 16 inputs or 8 connectors 32 inputs through 5 pin pluggable Eurostyle terminal screw connectors Relay Outputs 1 connector 1 output 16 inputs or 2 connectors 2 outputs 32 inputs Form C relays through 3 pin Eurostyle terminal screw connectors Communication SensorNet 32 devices per port at a maximum distance of 1 km...

Отзывы: