SETUP

Alarm-only Sequencing on Output B

As shipped, MONITOR output B provides a continuous
sequence of the video inputs.  To set up the unit such that
output B shows the sequence only during alarms, and is
otherwise blank, Jumper J45 on the main printed circuit board
(PCB) must be removed, as follows:

1. Turn unit off and unplug from power source.
2. Remove screws for top cover, and remove the top

cover.

3. Remove jumper J45, located near the middle of the

main PCB.  See Figure 2, page 3,  for location of J45.

4. Reattach top cover.

Audio Alarm Beeper

As shipped, the audio alarm beeper is activated during alarms.
To deactivate the beeper, remove Jumper J46, located near the
side of the printed circuit board.  See Figure 2, page 3, for the
location of jumper J46.  Follow the procedures outlined above
for access to the main PCB for removing this jumper.

Cascading Setup

Two switchers may be cascaded together to provide for a 32
position switcher, as described in Cascading Connections, page
4.  As shipped, the first switch position of DIP switch S22 is
set for non-cascaded operation.  It must be reset for cascaded
operation, as shown in the following paragraph.

On-Screen Camera Numbers

On-screen camera numbers displayed by the switcher may be
set to provide for any block of 16 camera numbers, from 1 to
512.  A six-position DIP switch (S22) located on the main PCB
of the switcher is used to set the 16-camera block of on-screen
camera numbers.  As shipped, all units are set for camera block
1-16.  Table 1, DIP Switch S22 Camera Block Settings, shows
the correct setting of the DIP switch positions for other camera
number blocks.

Follow the procedures outlined for Alarm-only Sequencing
above for access to the main PCB to set this DIP switch.  See
Figure 2, page 3 for location of DIP switch S22.

Table 1 -  DIP Switch S22 Camera Block Settings

0 = OFF;  1 = ON

Camera               DIP Switch Position

Block

1

2

3

4

5

6

1-16

0

0

0

0

0

*

17-32

1

0

0

0

0

*

33-48

0

1

0

0

0

*

49-64

1

1

0

0

0

*

65-80

0

0

1

0

0

*

81-96

1

0

1

0

0

*

97-112

0

1

1

0

0

*

113-128

1

1

1

0

0

*

129-144

0

0

0

1

0

*

145-160

1

0

0

1

0

*

161-176

0

1

0

1

0

*

177-192

1

1

0

1

0

*

193-208

0

0

1

1

0

*

209-224

1

0

1

1

0

*

225-240

0

1

1

1

0

*

241-256

1

1

1

1

0

*

257-272

0

0

0

0

1

*

273-288

1

0

0

0

1

*

289-304

0

1

0

0

1

*

305-320

1

1

0

0

1

*

321-336

0

0

1

0

1

*

337-352

1

0

1

0

1

*

353-368

0

1

1

0

1

*

369-384

1

1

1

0

1

*

385-400

0

0

0

1

1

*

401-416

1

0

0

1

1

*

417-432

0

1

0

1

1

*

433-448

1

1

0

1

1

*

449-464

0

0

1

1

1

*

465-480

1

0

1

1

1

*

481-496

0

1

1

1

1

*

497-512

1

1

1

1

1

*

*

Cascading Setup: Switch position 6 OFF for single unit
operation (as shipped).  For cascading, set switch 6 on first
unit to ON and leave switch 6 on second unit set to OFF.

2

SETUP

AD1416,AD1416L

-  CAUTION  -

The following internal adjustments expose hazardous-

voltage components and allow access to dangerous

electric shock potentials.  They should be made only by

qualified service personnel.

Содержание AD1416

Страница 1: ...L Sequential Switchers The AD1416 and AD1416L are 16 position sequential video switchers with automatic alarm callup and two video outputs One video output provides the sequence of selected video inpu...

Страница 2: ...he purchaser under a license for use on a single system Information furnished by AMERICAN DYNAMICS is believed to be accurate and reliable However no responsibility is assumed by AMERICAN DYNAMICS for...

Страница 3: ...sons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the...

Страница 4: ......

Страница 5: ...io Alarm Beeper 2 Cascading Setup 2 On Screen Camera Numbers 2 CONNECTIONS 4 Video Inputs 4 Video Outputs 4 Alarm Inputs 4 Auxiliary Inputs Outputs 4 Power 4 OPERATION 5 Front Panel Controls 5 On Scre...

Страница 6: ......

Страница 7: ...h modes sequence multiple alarms Form C Alarm contacts are available to control a VCR or other alarm device An audible alarm beeper can be deactivated Logic level outputs of the on screen camera numbe...

Страница 8: ...itch S22 located on the main PCB of the switcher is used to set the 16 camera block of on screen camera numbers As shipped all units are set for camera block 1 16 Table 1 DIP Switch S22 Camera Block S...

Страница 9: ...P CONNECTIONS 3 Figure 2 Location of Jumpers and DIP Switch on main PCB Figure 3 AD1416 Rear Panel MONITOR J1 J2 120V 60Hz CAMERA A B 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 13 J3 Front JUMPER J45 U7 U8 U...

Страница 10: ...cable and panel labels for cameras 17 through 32 The lower of the two BNC connectors for each MONITOR output is used for cascading video Connect Output A of the master unit to Output A of the slave u...

Страница 11: ...These modes are AUTO Cameras called by alarm inputs are held on Output A for 10 seconds If the alarm is still active after 10 seconds the hold continues until the alarm clears If the alarm has cleare...

Страница 12: ......

Страница 13: ...Typical System Connections...

Страница 14: ...CAMERA 7 CAMERA 8 CAMERA 9 AD1461 MOTION DETECTORS VCR MONITOR ALARM CONTACT 6 ALARM CONTACT 7 ALARM CONTACT 8 ALARM CONTACT 9 IN OUT CONTROL IN OUT CONTROL CAMERA 1 IN OUT CONTROL CAMERA 10 ALARM CO...

Страница 15: ...TEM CONNECTIONS AD1416L with 8 Cameras and Looping Outputs CAMERA 8 CAMERA 7 CAMERA 6 CAMERA 5 17 18 19 20 2 3 4 1 6 7 8 5 10 11 12 9 14 15 16 13 MONITOR J1 J2 120V 60Hz CAMERA A B J3 1 2 3 4 5 6 7 8...

Страница 16: ...20V 60Hz CAMERA A B 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 13 J3 CAMERA 1 MONITOR J1 J2 120V 60Hz CAMERA A B 17 18 19 20 21 22 23 24 25 26 27 28 30 31 32 29 J3 CAMERA 17 AD1416 C 4 VCR MONITOR CAMERA 32...

Страница 17: ...Index...

Страница 18: ...ts 4 Video Outputs 4 FEATURES 1 Front Panel Controls 5 INSTALLATION 1 Mounting 1 J1 and J2 Pin Locations 3 Location of Jumpers and DIP Switch on main PCB 3 On Screen Camera Numbers Setup 2 On Screen D...

Страница 19: ...IF YOU ENCOUNTER ANY PROBLEMS OPERATING THIS UNIT OR NEED ASSISTANCE CALL OUR TECHNICAL SUPPORT CENTER within the United States 1 800 442 2225 outside the United States 914 624 7640...

Страница 20: ...5 914 624 7600 Technical Support Center 1 800 442 2225 FAX 914 624 7685 8000 1787 01 Revision C Printed in U S A June 1995 SPECIFICATIONS Supply Voltage AD1416 AD1416L 120VAC 50 60 Hz AD1416X AD1416LX...

Отзывы: