A power supply with voltage levels below the
operational requirements of the Illuminator will
result in substantial loss of IR energy output,
causing a loss of viewing range.
•
A power supply with remote sensing
capabilities is desirable. Remote sensing
compensates for voltage drops across
extended lengths of power supply-to-Illuminator
connection wiring. (Remote sensing capability
is defined as a power supply having internal
circuitry to automatically compensate for any
voltage drop caused by changes in the load
demand and/or long wire lengths between the
power supply and the Illuminator.)
Twilight Switch
American Dynamics recommends routing the AC
source voltage through a twilight switch (not
supplied). A daylight activated on/off switch
prevents the IR-Illuminator from possible over-
heating by intense sunlight.
Power Supply Installation
This installation should be made by qualified
service personnel and should conform to all local
codes. Safeguards must be taken to avoid
unintentional operation by employees and
maintenance personnel working about the
premises.
General Safety
The instructions in this document are for the
installer's safety and should be observed without
exception:
•
Before installation, become familiar with all the
special features and warnings associated with
this equipment. Once installation is complete,
store this document in a safe, convenient
location for future reference.
•
At close range, Infrared light can seriously
damage a person's vision. Install this
Illuminator in such a manner as to provide a
minimum safety zone of 1.22m (4ft) between
the Illuminator and the closest possible human
contact.
1040-3060PSA Power Supply
Installation
The 1040-3060PSA Power Supply is provided with
a NEMA-4 weatherproof enclosure. Mount the
power supply close to the Illuminator installation
site.
Notes:
•
Inspect the area around the proposed
installation site for wires, pipes, or obstructions
that may interfere with the installation.
•
Mount all hardware (twilight switches, junction
boxes, power supply, and Illuminator) before
laying out conduit and wiring (Figure 2).
•
The installation shown in Figure 2is for
illustration purposes only. Hardware items such
as conduit, junction boxes, twilight switches,
and inter-connection wiring are user-supplied.
The power supply enclosure has four mounting
holes for direct wall or panel mounting (Figure 1).
Figure 1. Weatherproof enclosure mounting
dimensions
•
Confirm a structurally sound surface for the
mounting location.
•
Make a template of the enclosure mounting
holes or place the enclosure against the
mounting surface and mark the four hole
locations.
•
Drill the four holes and attach the enclosure to
the mounting surface.
152.4mm
(6.0")
273mm