3

  A power supply with voltage levels below the

operational requirements of the Illuminator will
result in substantial loss of IR energy output,
causing a loss of viewing range.

  A power supply with remote sensing

capabilities is desirable. Remote sensing
compensates for voltage drops across
extended lengths of power supply-to-Illuminator
connection wiring. (Remote sensing capability
is defined as a power supply having internal
circuitry to automatically compensate for any
voltage drop caused by changes in the load
demand and/or long wire lengths between the
power supply and the Illuminator.)

Twilight Switch

American Dynamics recommends routing the AC
source voltage through a twilight switch (not
supplied). A daylight activated on/off switch
prevents the IR-Illuminator from possible over-
heating by intense sunlight.

Power Supply Installation

This installation should be made by qualified
service personnel and should conform to all local
codes. Safeguards must be taken to avoid
unintentional operation by employees and
maintenance personnel working about the
premises.

General Safety

The instructions in this document are for the
installer's safety and should be observed without
exception:

  Before installation, become familiar with all the

special features and warnings associated with
this equipment. Once installation is complete,
store this document in a safe, convenient
location for future reference.

  At close range, Infrared light can seriously

damage a person's vision. Install this
Illuminator in such a manner as to provide a
minimum safety zone of 1.22m (4ft) between
the Illuminator and the closest possible human
contact.

1040-3060PSA Power Supply
Installation

The 1040-3060PSA Power Supply is provided with
a NEMA-4 weatherproof enclosure. Mount the
power supply close to the Illuminator installation
site.

Notes:

  Inspect the area around the proposed

installation site for wires, pipes, or obstructions
that may interfere with the installation.

  Mount all hardware (twilight switches, junction

boxes, power supply, and Illuminator) before
laying out conduit and wiring (Figure 2).

  The installation shown in Figure 2is for

illustration purposes only. Hardware items such
as conduit, junction boxes, twilight switches,
and inter-connection wiring are user-supplied.

The power supply enclosure has four mounting
holes for direct wall or panel mounting (Figure 1).

Figure 1.  Weatherproof enclosure mounting
dimensions

  Confirm a structurally sound surface for the

mounting location.

  Make a template of the enclosure mounting

holes or place the enclosure against the
mounting surface and mark the four hole
locations.

  Drill the four holes and attach the enclosure to

the mounting surface.

152.4mm

(6.0")

273mm

(10.75")

Содержание AD1020-1541

Страница 1: ...a license for use on a single system Information furnished by AMERICAN DYNAMICS is believed to be accurate and reliable However no responsibility is assumed by AMERICAN DYNAMICS for its use nor for an...

Страница 2: ...oduct for service Do not attempt to service this product yourself Opening or removing covers may expose you to dangerous voltages or other hazards Refer all servicing to qualified personnel Descriptio...

Страница 3: ...Before installation become familiar with all the special features and warnings associated with this equipment Once installation is complete store this document in a safe convenient location for futur...

Страница 4: ...ponents B C and D of the liquid tight hub Figure 3 into an appropriate pass through Note Hub B fits through the O ring D on the outside of the enclosure and is secured by nut C on the inside of the en...

Страница 5: ...osure by means of the double sided tape provided Tighten the bushing Caution If necessary trim the MOV surge suppressor leads to keep them as short as possible After the leads are connected to the ter...

Страница 6: ...he S V terminals Connect the proper input supply voltage 120Vac or 230Vac to the input terminals Confirm a reading of 13 5 0 1Vdc If necessary adjust the Voltage Adjustment Potentiometer VR51 Adjustin...

Страница 7: ...0 3060PSA Power Supply uses remote sensing to maintain a constant voltage at the Illuminator A 4 wire configuration between the power supply and the Illuminator maintains the correct load voltage over...

Страница 8: ...0 watt illuminator AWG Distance 12 0m 30 5m 0 100 14 0m 22 9m 0 75 16 0m 15 2m 0 50 Troubleshooting PROBLEM POSSIBLE CAUSE SOLUTION Lamp does not come on No 13 5 Vdc to Lamp Check 120 Vac or 230 Vac s...

Страница 9: ...020 SERIES 30 60 WATT LED INFARED ILLUMINATOR 8000 1794 01 REV A 9 Dimensions Figure 8 1020 series Illuminator dimensions 30 60 Watt model 65mm 2 56 182mm 7 17 127mm 5 0 2mm 08 21mm 83 6mm threaded ho...

Страница 10: ...range 22m 72ft 20m 66ft 20m 66ft 55m 180ft 42m 138ft 35m 115ft ELECTRICAL Operating Voltage 13 5Vdc 13 5Vdc 13 5Vdc 13 5Vdc 13 5Vdc 13 5Vdc Current Amps 2 5A 2 5A 2 5A 4 6A 4 6A 4 6A ALL UNITS Service...

Страница 11: ...sible for FCC compliance could void the user s authority to operate the equipment and could create a hazardous condition Other Declarations WARRANTY DISCLAIMER Sensormatic Electronics Corporation make...