background image

OPERATION 

SELECT 

FREEZE 

RUN 

A L A R M S  

QUAD 

Figure 

Front Panel Controls 

OPERATION 

The 

1473 

may be  used 

with 

one 

or 

two monitors. 

If  only one monitor is used, 

it 

should 

be 

the Call Monitor.  The 

Call Monitor displays either: 

1. 

A sequence of  full-screen camera pictures, 

with 

or 

without 

the 

Quad 

Display 

(see 

RUN, 

below). 

2. 

selected full-screen picture of  any camera or  the  Quad 

Display 

(see 

3.4, 

and QUAD below). 

The 

Quad Monitor always shows the Quad Display. 

Front Panel 

Operation 

white 

box 

is displayed 

in 

the  bottom  center of  the Quad 

display when alarms are enabled (Figure 

5). 

2.  If 

any  alarm is active on  a camera 

input, 

the 

ALARMS 

action is an  acknowledge of  the 

(see 

Alarm 

Mode 

Setup, page 

3). 

Video 

Loss 

Detection 

Loss 

of  video to any  input is  detected by  the 

1473. 

When 

video  loss is  detected, the  corresponding quadrant displays  a 
blanked screen on 

the 

Quad display.  The last picture received 

before  video  loss  is  stored 

in 

memory.  If  the  FREEZE 

pushbutton is activated following a video loss, the frozen Quad 
display  includes 

the 

last picture  received,  shown 

in  the 

appropriate quadrant 

The 

front panel controls (see Figure 

5 )  

operate 

as 

follows. 

Alarm Action 

1, 

Each of  these pushbuttons 

calls a full-screen display 

of 

the corresponding camera to the Call Monitor. 

Q U A D  

This pushbutton calls a display of  four cameras 

(in 

Quad 

configuration) to the Call Monitor. 

FREEZE: 

Alternate 

pushbutton 

FREEZE 

action: 

1. 

Freezes  the  current Quad display  on  both  the  Call and 

Quad 

Monitors.  The Quad display  also 

flashes 

the  word 

"FROZEN" 

(see Figure 

6) 

and shows the  last  picture 

received before video loss, 

if 

video loss had been detected. 

2. 

Restores the 

Quad display. 

RUN:  The RUN pushbutton action sequences the four camera 

inputs on  the Call Monitor.  The  sequence rate,  either two 

or 

four 

is 

selected by  the jumper 

J3 

1. 

To 

include 

the  Quad display 

in 

the  sequence, set jumper 539  to  the 

"IN" 

position (see 

Quad Sequence Setup, page 

Activating the RUN pushbutton while a sequence is running 

has 

no  effect.  Activating  any  of  the 

1, 

2, 

or  QUAD 

pushbuttons stops  the  sequence and  calls the  requested 
display 

to 

the 

Monitor. 

ALARMS: 

The 

ALARMS 

pushbutton action depends on  the 

current mode of the 

unit: 

1. 

If 

no 

alarms 

are  active, alternate 

ALARMS 

pushbutton 

action 

enables 

or 

disables 

alarm 

response action 

in 

the unit. 

Alarm 

contact closures on any of  the 

Alarm 

Input pins activate 

the following response actions 

if 

the unit is enabled for alarms: 

1. 

The  word  "ALARM!"  flashes on  the  Quad  display to 

indicate the presence of 

an 

alarm (Figure 

6). 

2. 

The Call Monitor displays a full-screen picture of  one, or a 
sequence of  multiple, alarmed cameras.  The Quad display 
may  be  included 

in 

this sequence by  the  setting of  jumper 

J39 

(see 

Quad  Sequence Setup, page 

3). 

Alarm 

sequence 

dwell time is 

at 

two seconds. 

3. 

The 

alarm 

relay  is activated for control of 

external 

devices. 

Each  individual camera 

can 

be 

set  for one of  three different 

alarm 

clearance modes,  selectable by  a 

three 

position jumper 

(see 

Alarm Modes Setup, page 

3). 

After the 

alarm 

is cleared or 

acknowledged, the Call Monitor display 

returns 

to 

the  camera 

it 

was last displaying, before the 

alarm 

occurred. 

Blinks  when  an  alarm  is  received 

Blinks  when  Quad  display  is  frozen 

White  box  displayed  when 
alarms  are  enabled 

Figure 6 

Quad Displays 

Содержание 1473 QuadView I1

Страница 1: ...1473 QuadView 1 1 a four quadrant multiplexer digitally captures the video from four video sources reduces these images to quarter screen size and combines them onto a QUAD output A separate CALL outp...

Страница 2: ...s furnished to the putchaser under a license foruse on a single system Information furnished by AMERICAN DYNAMICS is believed to be accurate and reliable However no responsibility is assumed by AMERIC...

Страница 3: ...bookket prepared by the Federal Communications Commission helpful How t o Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washingt...

Страница 4: ...Table of Contents System Description 1 Features 1 Installation 1 Connections 2 Setup 3 Operation 4 Typical System Connections Appendix Troubleshooting Inside Back Page Specifications Back Page...

Страница 5: ...he corresponding alarm input is activated multiple alarmsare sequenced on the Call monitor ThreedifferemAhnn Clearancemodes are available 1 Alarm cleared whenacknowledged 2 Alarm automaticallycleared...

Страница 6: ...tput which can be used as a sequence monitor and one to the Quad output which alwayspresents the quad format PowerconnectifM Connect the appended 3 wire cord to the required power source according to...

Страница 7: ...essing the ALARMS pushbutton or by an input of a remote alarmacknowledge pin 13 MODE 2 Holds the alarm for twenty seconds for an alarm input of twenty seconds and less For longer alarm inputs holds th...