12
American Dryer Corp.
113604 - 4
When a cycle is running, the control will display DIAGNOSTIC
MODE at the top of the display.
If a fault occurs during Diagnostic Mode, the control will enter into
a fault cool down and the occurring fault will be displayed. The
fault can be cleared by reentering the diagnostic cycle.
3: HELP MENU
The help menu allows the user to view the status of different
parts of the dryer. When a feature is highlighted, the center section
will list that feature and its current status. The items in the help
menu will refer to the current running cycle that was selected in
Diagnostic Mode.
Pressing the HI/UP ARROW key will allow the user to move the
highlighted bar around the help menu screen. For example,
highlighting “S” will show the status of the sail switch.
Pressing the PAUSE/STOP key will return the controls to
Diagnostic Mode.
The table below shows the standard features available and the
symbol they correlate with.
HELP
CODE
CODE DESCRIPTION
81
Lower Exhaust Probe Fault
86
Upper Exhaust Probe Fault
87
Upper Axial Probe Fault
82
Lower Axial Probe Fault
89
Upper Sail Switch Open Fault
88
Upper Sail Switch Closed Fault
84
Lower Sail Switch Open Fault
83
Lower Sail Switch Closed Fault
90
Upper Rotation Sensor Fault
91
Lower Rotation Sensor Fault
92
Gen 2 Card Reader Communication Fault
E1
Top Radiant Sensor fault count
E2
Top Burner Ignitor fault count
E3
Top Exhaust High Limit
E4
Bottom Radiant sensor fault count
E5
Bottom Burner Ignitor fault count
E6
Bottom Exhaust High Limit
E7
Coin 1 Bad Coin count
E8
Coin 2 Bad Coin Count
E9
Upper pocket forward rotation sensor fault count
EA
Upper pocket reverse rotation sensor fault count
EB
Lower pocket forward rotation sensor fault count
EC
Lower pocket reverse rotation sensor fault count
ED
S.A.F.E. DISABLED – Water not connected
If a fault occurs while in Help Mode, the fault will be
displayed as a Help Code or Event Code.
Codes can be cleared by pressing and holding the
PAUSE/STOP key for 3-seconds.
The last item listed in the code menu will identify the
revision of the software that is being used on the control
board.
If the help menu feature “CODE” is selected, the center
section will present “Help Codes” and “Events”. All of the
items in the code menu will automatically scroll up and
continue to scroll until LOW/DOWN ARROW key is
pressed to select a new help menu feature.
All CODES starting with an “H” represent some condition
that could interfere with the proper functioning of the dryer.
There could be up to 3 “H” codes listed within the HELP
MENU.
•
H1 represents the last failure recorded.
•
H2 represents the second to last failure recorded.
•
H3 represents the third to last failure recorded.
Each Help Code will be followed by a two digit code. This
two digit code will reflect a particular issue.
FEATURE
SYMBOL
FEATURE
TEXT
FEATURE
FEATURE
INFORMATION
EXH
EXHAUST
TEMP PROBE
Exhaust
Temperature Probe
(in Deg. F or C)
AXL
AXIAL TEMP PROBE
Axial Thermistor Probe
(in Deg. F or C)
RPM
TUMBLER
ROTATION SPEED
Tumbler Speed in
Revolutions Per Minute
R.P.M.
MIN
TIME REMAINING
Time remaining
in the diag. cycle
0 to 99
(in minutes)
CODE
HELP CODE MENU
Help Menu Code
Help Codes
T1
THERMOSTAT
BURNER 1
Thermostat
(Heat Output Burner 1)
ON - OFF
T2*
THERMOSTAT
BURNER 2
Thermostat
(Heat Output Burner 2)
ON - OFF
H1
HEAT RETURN
BURNER 1
Heat Return Burner 1
ON - OFF
H2*
HEAT RETURN
BURNER 2
Heat Return Burner 2
ON - OFF
C1
HEAT RELAY 1
CONTACTS
Heat relay 1 contacts
OPEN - CLOSED
C2*
HEAT RELAY 2
CONTACTS
Heat relay 2 contacts
OPEN - CLOSED
B
BLOWER
Fan output
ON - OFF
F
FORWARD
Forward drive output
ON - OFF
R
REVERSE
Shows reversing
relay is on
ON - OFF
D
DOOR
Main Door
OPEN - CLOSED
L
LINT
Lint Door
OPEN - CLOSED
P
WATER PRESSURE
H
2
O Input
ON - OFF
S
SAIL SWITCH
Sail Switch
OPEN - CLOSED
V
VAULT SWITCH
Vault Switch
OPEN - CLOSED
W
WATER OUTPUT
S.A.F.E. output
ON - OFF