Warning

Electrical power must be provided to the dryer
at all times.  If the main electrical power supply

to the dryer is disconnected, the fire suppression
system is inoperative!!

Preparation for Operation/Start-Up __

The following items should be checked before attempting to
operate the dryer:

• Read all “CAUTION,” “WARNING,” and “DIRECTION”

labels attached to the dryer.

• Check incoming supply voltage to be sure that it is the

same as indicated on the data label.  In the case of 208
VAC or 240 VAC, the supply voltage must match the
electric service exactly.

• GAS MODELS – Check to ensure that the dryer is

connected to the type of heat/gas indicated on the dryer
data label.

• GAS MODELS – Be sure that all gas shutoff valves are

in the open position.

• Be sure all back panels (guards) and electric box covers

are in place.

• Be sure the service doors are closed and securely in

place.

• Be sure the lint door/drawer is securely in place.

• Rotate the tumbler (drum) by hand to be sure it moves

freely.

• Check bolts, nuts, screws, terminals, and fittings for

tightness and security.

• Check that the vent is connected to the dryer and is

exhausted to the outdoors.

• STEAM MODELS – Check to ensure all steam shutoff

valves are open.

Preoperational Test __________________

All dryers are thoroughly tested and inspected before leaving
the factory.  However, a preoperational test should be
performed before the dryer is publicly used.  It is possible
that adjustments have changed in transit or due to marginal
location (installation) conditions.

Turn on electric power to the dryer.

Refer to the Operating Instructions for starting your particular
model dryer.

Gas Dryers

Open all shutoff valves.

When a gas dryer is first started (during initial start-up), it
has a tendency not to ignite on the first ignition attempt.  This
is because the gas supply piping is filled with air, so it may
take a few minutes for the air to be purged from the lines.

Note: During the purging period, check to be sure that all
gas shutoff valves are open.

A gas pressure test should be taken at the gas valve pressure
tap of each dryer to ensure that the water column pressure is
correct and consistent.

!

Note: Water column pressure requirements (measured at
the pressure tap of the gas valve body) must be verified.

Important: In most cases there is no regulator provided in
an L.P. dryer.  The water column pressure must be
regulated at the source (L.P. tank), or an external regulator
must be added to each dryer.

Electrical Dryers

Check to ensure that electric oven/contactor assembly is
activating.

Safety Related Circuits

Make a complete operational check of all safety related
circuits:

• Door Switch(es)

• Hi-Limit Thermostats

• Sail Switch

Make a complete operational check of all operating controls.

Tumbler Coating

The tumbler is treated with a protective coating.  We suggest
dampening old garments or cloth material with a solution of
water and nonflammable mild detergent and tumbling them
in the tumbler to remove this coating.

Microprocessor Programs/Selections

Each microprocessor controller (computer) has been
preprogrammed by the factory with the most commonly used
parameter (program) selections.  If computer program
changes are required, refer to the computer programming
manual, which was shipped with the dryer.

Preoperational Instructions __________

Important: For more detailed information regarding the
microprocessor controller (computer), refer to the
microprocessor user’s manual included with the dryer.

Coin Models

Microprocessor Controller (Computer)

When the microprocessor controller (computer) is in the ready
state, the L.C.D. screen will display “Ready, Insert $XX.XX
(amount) to Start”.

Insert coin(s).  Once the correct “Amount to Start” has been
inserted, the L.C.D. will display “Select Temperature”.

Select temperature by pressing “HI,” “MED,” or “LO.”  The
cycle will start and the L.C.D. will display the Dry Cycle
selected and the remaining time.

The dryer will continue through the drying and cooling cycles,
until the vended time has expired.

Note: To stop the dryer, open main door.  Continuation of
the cycle will resume only after the door has been closed
and any one of the 3 temperature selections is pressed.

Содержание HBG76

Страница 1: ...r de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent être assurés par un installateur ou un service d entretien qualifié ou par le fournisseur de gaz WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion and...

Страница 2: ...________________________________________________________________ SERIAL NUMBER S __________________________________________________________________________________ ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained ...

Страница 3: ...ear dryer s in operation Under no circumstances should the dryer door switch es lint door drawer switch es or heat safety circuit s ever be disabled The dryer must never be operated with any of the back guards outer tops or service panels removed Personal injury or fire could result The dryer must never be operated without the lint filter screen in place even if an external lint collection system ...

Страница 4: ... that contain plastic foam sponge rubber or similarly textured rubber materials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard A program should be established for the inspection and cleaning of lint in the burner area exhaust ductwork and area around the back of the dryer The frequency of inspection and cleaning can best be determined from experience at each...

Страница 5: ...___________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ___________________________________________...

Страница 6: ...g APPROXIMATE SHIPPING WEIGHT 775 lb 351 53 kg AIRFLOW 60 Hz 600 cfm 16 99 cmm 50 Hz 500 cfm 14 16 cmm EXHAUST CONNECTION DIAMETER 8 20 32 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A OVEN SIZE kW Btu hr kcal hr 18 4 62 763 15 816 20 2 68 975 17 381 20 3 69 418 17 493 20 4 69 521 17 519 VOLTAGE AVAILABLE 120 240V 1ø 2 3w 50 60 Hz APPROXIMATE NET WEIGHT 745 lb 337 93 kg APPROXIMATE SH...

Страница 7: ...113615 1 www amdry com 7 Specifications _____________________________________________________________________ ...

Страница 8: ...st be located in an area where correct exhaust venting can be achieved as noted in this manual refer to Exhaust Requirements section Important The dryer should be located where a minimum amount of exhaust ducting will be necessary The dryer must be installed with adequate clearance for air openings into the combustion chamber Caution This dryer produces combustible lint and must be exhausted to th...

Страница 9: ...ergy and shutdown of the burner by the airflow sail switch burner hi limits or lint chamber hi limit protector thermostat The dryer must be installed with a proper exhaust duct connection to the outside The dryer shall not be exhausted into any gas vent chimney wall ceiling or concealed space of a building Caution This dryer produces combustible lint and must be exhausted to the outdoors Improperl...

Страница 10: ...he exhaust exits the building If the ductwork travels vertically up through the roof it should be protected from the weather by using a 180 turn to point the opening downward In either case allow at least twice the diameter of the duct between the duct opening and the nearest obstruction refer to the diagram Important Do not use screens louvers or caps on the outside opening of the exhaust ductwor...

Страница 11: ...yer The dryer must be connected to the electric supply shown on the data label In the case of 208 VAC or 240 VAC the supply voltage must match the electric service specifications of the data label exactly The wire size must be properly sized to handle the related current Warning 208 VAC and 240 VAC are not the same Any damage done to dryer components due to improper voltage connections will automa...

Страница 12: ... Important A strain relief must be used where the input wiring enters the oven assembly Electrically Heated Models Only The electrical input connections are made at the rear service box located at the right upper section of the dryer The ground connection is made to a copper lug also provided in this area To gain access remove rear service cover The only electrical input connections to the dryer a...

Страница 13: ...es equal to or less than 1 2 psig 3 5 kPa for non CE dryers or 50 mb for CE dryers Warning Fire or explosion could result due to failure of isolating or disconnecting the gas supply as noted Note Undersized gas piping will result in ignition problems slow drying increased use of energy and can create a safety hazard The dryer must be connected to the type of heat gas indicated on the data label an...

Страница 14: ... leaks by brushing on a soapy water solution liquid detergent works well Warning Never test for leaks with a flame TYPICAL L P GAS INSTALLATION Heat Input Gas Consumption Orifice Injector Data Shaded areas are stated in metric equivalents Gas valve s internal regulator disabled Consult factory for elevations over 2 000 feet 610 meters for correct orifice size NOTES ________________________________...

Страница 15: ...tion and check for leaks with soap solution with main burner ON Steam Information ____________________ It is your responsibility to have all plumbing connections made by a qualified professional to ensure that the steam plumbing installation is adequate and conforms with local state and country regulations or codes Care must be exercised when leveling steam dryers into final position After levelin...

Страница 16: ...d in metric equivalents The minimum operating pressure for optimum results is 100 psig 689 47 kPa Installation Instructions To ensure an adequate supply of steam is provided be sure that the steam supply lines and steam return lines are sized and laid out as stipulated in this manual Inadequate steam supply lines and steam return lines or improper steam plumbing will result in poor performance and...

Страница 17: ...at all gas shutoff valves are open A gas pressure test should be taken at the gas valve pressure tap of each dryer to ensure that the water column pressure is correct and consistent Note Water column pressure requirements measured at the pressure tap of the gas valve body must be verified Important In most cases there is no regulator provided in an L P dryer The water column pressure must be regul...

Страница 18: ...rom the factory by calling the Parts Department at 1 508 678 9000 or you may FAX in your order at 1 508 678 9447 Note When ordering replacement parts from the reseller or the manufacturer be sure to give them the correct model number and serial number so that your parts order can be processed in an expeditious manner Warranty Information _________________ Returning Warranty Cards Before any dryer ...

Страница 19: ...n every third or fourth load A clogged lint screen will cause poor dryer performance The lint door drawer is located just below the loading door of the dryer Open the lint door drawer brush the lint off the lint screen and remove the lint Inspect lint screen and replace if torn Note To remove the lint drawer from the dryer pull the drawer out loosen the torx screws on the sides of the rails This a...

Страница 20: ... steam 2 Serial Number Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular dryer gas either natural gas or L P gas electric or steam 4 Heat Input For Gas Dryers This describes the heat input in British thermal units per hour Btu hr or kilowatts kW 5 Orifice Size For Gas Dryers Gives the number drill size used 6 E...

Страница 21: ..._________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ __________________________...

Страница 22: ...ADC Part No 113615 1 07 24 08 22 ...

Отзывы: