19
2) Electric Models ONLY
ALL
electrically heated dryers
must
be
connected to the electric service shown on the dryer’s
data label, which is affixed to the left side panel area behind the top control (access) door. The
connecting wires
must be
properly sized to handle the rated current.
NOTE:
Electrically heated service (amperage) specifications/requirements
are not
available at the time
of printing. Contact factory for update.
NOTE:
Component failure due to improper voltage application will VOID THE WARRANTY.
3. Grounding
A ground (earth) connection
must be
provided and installed in accordance with state and local codes. In
the absence of these codes, grounding
must conform
to applicable requirements of the National Electrical
Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation
must conform
to applicable
Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The
ground connection may be to a proven earth ground at the location service panel.
For added personal safety, when possible, it is suggested that a separate ground wire (no. 18 minimum) be
connected from the ground connection of the dryer to a grounded cold water pipe.
DO NOT
ground to a
gas pipe or hot water pipe
.
The grounded cold water pipe must have metal to metal connection
ALL
the
way to the electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic,
rubber, or other insulating connectors, they
must be
jumped out with no. 4 copper wire and securely
clamped to bare metal at both ends.
IMPORTANT:
For personal safety and proper operation, the dryer
must be
grounded.
Provisions are made for ground connection in each dryer at the electrical service connection area.
4. Electrical Connections
A wiring diagram is located inside the control box for
connection data.
a. Gas Models and Steam Models ONLY
NOTE: A CIRCUIT SERVICING EACH DRYER
MUST BE
PROVIDED.
1) Single-Phase (1ø) Wiring Connections/Hookup
The electrical input connections on
ALL
single-phase
(1ø) gas model dryers and steam model dryers are
made into the rear service box located at the upper
left area of the dryer.