4
American Dryer Corp.
113159-2
SECTION II
SPECIFICATIONS/COMPONENT IDENTIFICATION
A. SPECIFICATIONS
Shaded areas are stated in metric equivalents
4/27/04
*
Air-operated steam damper system must be provided with clean, dry and regulated 80 psi +/- 10 psi (5.51 bar +/- 0.69 bar) air supply.
** Water supply must be 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) for the fire suppression system to operate properly.
IMPORTANT:
Steam dryers
must be
provided with a clean, dry, and regulated 80 psi +/- 10 psi
(5.51 bar +/- 0.68 bar) air supply. Air volume requirement is 0.75 cfh (cubic feet per
hour) (0.02 cmh [cubic meters per hour]).
NOTE: ADC
reserves the right to make changes in specifications at any time without notice or
obligation.
TUMBLER DIAMETER
37”
94 cm
TUMBLER DEPTH
36”
91.5 cm
TUMBLER VOLUME
22.4 cu ft
0.634 cu m
TUMBLER MOTOR
1/2 hp
0.373 kW
BLOWER MOTOR
3 hp
2.2 kW
DOOR OPENING (DIAMETER)
21-1/2”
54.6 cm
EXHAUST CONNECTION (DIAMETER)
14”
35.56 cm
AIRFLOW
1,700 cfm
48.14 cmm
DRYERS PER 20’/40’ CONTAINER
10 / 20
DRYERS PER 48’/53’ TRUCK
24 / 26
WATER CONNECTION**
3/4”-11.5 NH
VOLTAGE AVAILABLE
208-480v 3ø 3, 4w 50/60 Hz
APPROX. NET WEIGHT
833 lbs
377.8 kg
APPROX. SHIPPING WEIGHT
883 lbs
400.5 kg
HEAT INPUT
270,000 Btu/hr
68,040 kcal/hr
INLET PIPE CONNECTION
1” F.N.P.T.
VOLTAGE AVAILABLE
208-480v 3ø 3, 4w 50/60 Hz
APPROX. NET WEIGHT
928 lbs
420.9 kg
APPROX. SHIPPING WEIGHT
978 lbs
443.6 kg
COMPRESSED AIR VOLUME
0.75 cfh
0.02 cmh
COMPRESSED AIR CONNECTION
1/8” F.N.P.T.
STEAM CONSUMPTION
375 lbs/hr
170.5 kg/hr
OPERATING STEAM PRESSURE
125 psi max
8.6 bar
BOILER HP NORMAL LOAD
11
SUPPLY CONNECTION
1” F.N.P.T.
RETURN CONNECTION
1” F.N.P.T.
Gas
Steam*
Содержание AD-81 III