23
To Replace Lint Compartment Hi-Heat Protector (225º F [107º C]) Thermostat
This thermostat is part of the “sensor bracket assembly” and is secured to the underside of the basket (tumbler)
wrapper in the lint compartment. As a safety device, this thermostat will open (shut off) the heating unit circuit
if an excessive temperature occurs. The dryer motors will remain on, even if the thermostat is open.
IMPORTANT:
Under no circumstances should heat safety devices be disabled.
1. Discontinue electrical power to the dryer.
2. Remove lint drawer. Remove two (2) screws securing
lint door and remove lint door.
3. Locate sensor bracket assembly and loosen the two
(2) Phillips head screws securing bracket assembly to
the basket (tumbler) wrapper.
NOTE:
DO NOT
remove the screws.
4. Remove bracket assembly by slightly sliding bracket
towards the rear of the dryer and to the left.
5. Disconnect sensor bracket harness connector and
remove bracket assembly from dryer.
6. Disconnect the two (2) orange wires from the thermostat.
7. Disassemble thermostat from bracket assembly by removing the two (2) mounting screws, washers, and
nuts.
8. Reverse this procedure for installing a hi-heat protector thermostat.
9. Reestablish electrical power to the dryer.
D. SAIL SWITCH ASSEMBLY (GAS MODELS ONLY)
The sail switch is a heat circuit safety device which controls the burner circuit only. When the dryer is operating
and there is proper airflow, the sail switch damper pulls in and closes the sail switch. Providing
ALL
the other
heat-related circuits are functioning properly, ignition
should now be
established. If an improper airflow occurs,
the sail switch damper will release, and the circuit will open.