The neutral will only be used on 4-wire service. This is typical for 380-416V, 50 Hz.
b. Electrically Heated Models Only
The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and
sometimes neutral) and ground. Single-phase (1ø) power for the control circuit and for any
single-phase (1ø) motors (if present) is done internally to the dryer by the factory at the oven contactor.
No single-phase (1ø) input connection is required on a 3-phase (3ø) dryer.
CAUTION:
The dryer
must be
grounded. A ground lug has been provided for this purpose.
Input connection wiring
must be
sized properly to
handle the dryer’s current draw. This information is
printed on the dryer’s data label.
The electrical input connections are made at the electric
oven contactor located inside the assembly at the rear
center upper section of the dryer. The ground
connection is made to a copper lug also provided in
this area. To gain access, remove oven rear service
cover.
IMPORTANT:
A strain relief
must be
used where
the input wiring enters the oven
assembly.
2) 3-Phase (3ø) Wiring Connections/Hookup
The electrical connections on
ALL
3-phase (3ø) gas dryers are made into the rear service box
located at the upper left area of the dryer. The electrical connections are made at the power
distribution block located in the service box. The ground connection is made to the copper lug, also
provided in this box. To gain access, the service box cover
must be
removed.