Fixture Cleaning:
Due to fog residue, smoke, and dust cleaning the fixture should be
carried out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside
casing every 20 days.
2. Use a small brush and normal glass cleaner with a soft cloth to
wipe down the inside casing every 30-60 days.
3. Always be sure to dry all parts completely before plugging the
unit back in.
4. Frequent cleaning will extend lamp life and ensure fixture reliability.
Cleaning frequency depends on the environment in which the fixture
operates (I.e. smoke, fog residue, dust, dew). In heavy use we recom-
mend cleaning on a monthly basis. Periodic cleaning will ensure
longevity, and crisp beam output.
Strobe Ball™
Cleaning
©
American DJ Supply
®
- www.americandj.com - Strobe Ball™ Instruction Manual Page 6
Trouble Shooting:
Listed below are a few common problems and solutions you should try
before contacting customer support.
Unit rotates but has no light output from the unit;
1. Be sure you have connected your unit into a matching wall outlet.
2. Remove the lamp cover and be sure the lamp is seated in its
socket properly. Occasionally lamps become loose during shipping
be sure the lamp is push in to its socket all the way.
3. Be sure the lamp is good.
4. If the lamps was recently replaced, be sure the lamp probes are
properly inserted in the socket assemble.
Unit does not rotate and lamp does not turn on;
1. Be sure you have connected your unit into a matching wall outlet.
2. Be sure the external fuse has not blown. The fuse is located on the
side panel of the unit.
3. Be sure the power cord is properly seated in the power outlet.
4. Be sure your main power outlet has power.
Strobe Ball™
Trouble Shooting
Strobe Ball™
Halogen Lamp Warning
This fixture is fitted with halogen lamps which are
highly susceptible to damage if improperly handled.
Never touch lamp with your bare fingers as the oil
from your hands will shorten lamp life. Also, never
move the fixture until the lamps have had ample
time to cool. Remember, lamps are not covered
under warranty conditions.
Strobe Ball™
Lamp Replacement
Caution:
Always replace with the exact same type lamp, unless oth-
erwise specified by an authorized American DJ
®
technician. Replace
with anything other than the specified part can damage your unit and
will void your manufactures warranty.
Warning:
If after you have replaced the lamp and you continue
to blow lamps, STOP using the unit. Contact customer support for
further instructions, you may have to return the unit for servicing.
Continuing to use the unit may cause serious damage.
Reset Breaker:
To reset the breaker, push the breaker button in until you hear it pop
back in to place. If the breaker continues to pop, stop using the unit
and contact customer support the unit may require service.
Lamp Replacement:
Caution! Never attempt to change the lamp while the fixture is plugged
in and running. Always disconnect main power and allow the unit
ample time to cool before attempting to replace the lamp.
1. Be sure to follow all the proper handling procedures included with
your new halogen lamp.
Never touch the new lamp with your
bare fingers.
2. Remove the three thumb screw that secure the upper half of the
dome to the lower half.
3. Carefully pull up the upper half of the dome to expose the lamp.
4. Remove and replace the lamp.