Scatter Beam™
Lamp Replacement
Caution:
Always replace with the exact same type lamp and fuse,
unless otherwise specified by an authorized American DJ
®
techni-
cian. Replace with anything other than the specified part can damage
your unit and will void your manufactures warranty.
Warning:
If after you have replaced the lamp or fuse and you con-
tinue to blow either one, STOP using the unit. Contact customer sup-
port for further instructions, you may have to return the unit for ser-
vicing. Continuing to use the unit may cause serious damage.
Lamp Replacement:
Caution! Never open the unit when in use.
Always disconnect the main power and allow the fixture ample time
to cool before attempting to replace the lamp. Lamp replacement has
been made simple by incorporating a remove tray that is retained by
a single thumb screws. Again, please remember to always replace
with the exact same type lamp.
1. Be sure to follow the proper procedures when handling halogen
lamps. Never touch the new lamp with your bare fingers.
2. Unscrew the single thumb screw located on the top of the unit.
3. Once the thumb screw has been remove, pull back the lamp
assembly cover plate to expose the lamp.
4. Remove and replace the lamp with an exact match.
5. Reassemble in reverse order.
©
American DJ
®
- www.americandj.com - Scatter Beam™ Instruction Manual Page 6
©
American DJ
®
- www.americandj.com - Scatter Beam™ Instruction Manual Page 5
Halogen Lamp Warning!
This fixture is fitted with
halogen lamps which are highly susceptible to dam-
age if improperly handled. Never touch the lamps
with your bare fingers as the oil from your hands will
shorten lamp life. Also, never move the fixture until
the lamps have had ample time to cool. Remember,
lamps are not covered under warranty conditions.
Fixture Cleaning:
Due to fog residue, smoke, and dust cleaning the internal and exter-
nal lenses and dichroic colored dishes should be carried out periodi-
cally to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Use a soft brush to clean out the cooling vents
3. Clean the external optics with glass cleaner and a soft cloth every
20 days.
4. Clean the internal optics with glass cleaner and a soft cloth every
30-60 days.
5. Always be sure to dry all parts completely before plugging the unit
back in.
Cleaning frequency depends on the environment in which the fixture
operates (I.e. smoke, fog residue, dust, dew). In heavy use we recom-
mend cleaning on a monthly basis. Periodic cleaning will ensure lon-
gevity, and crisp beam output.
Scatter Beam™
Cleaning
Trouble Shooting:
Listed below are a few common problems and solutions you should
try before contacting customer support. For all other issues please
contact customer support.
Unit rotates but has no light output from the unit;
1. Be sure you have connected your unit into a matching wall outlet.
2. Remove the lamp cover and be sure the lamps are seated in their
sockets properly. Occasionally lamps become loose during ship-
ping be sure the lamps are push in to their sockets all the way.
3. Be sure the lamps are good.
Heads do not rotate and lamps do not turn on;
1. Be sure you have connected your unit into a matching wall outlet.
2. Be sure the external fuse has not blown. The fuse holder is locat-
ed on the bottom panel of the unit.
3. Be sure the unit power cord is properly seated in the power outlet
and the outlet has power.
4. Be sure the fuse holder is completely screwed in
Scatter Beam™
Trouble Shooting
Scatter Beam™
Breaker Reset
This unit is equipped with a built-in safety breaker. This breaker is
designed to close the power circuit in the event of an internal short
or power surge. This will reduce the risk of electrical shock or fire and
protect the circuitry. To reset the breaker, push the breaker button in
until you hear it pop back in to place. If the breaker continues to pop,
stop using the unit and contact our customer support team, the unit
may need to be returned for service.