background image

P

ower Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

P64  LED  UV.  The  American  DJ

®

  P64  LED  UV  is  available  in  a  120v 

and 220v version. Because line voltage may vary from venue to venue, 
you should be sure your unit voltages matches the wall outlet voltage 
before attempting to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. A DMX controller sends DMX data instructions from 
the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 
controller,  as  long  as  all  fixtures  and  the  controller  are  DMX  compli-
ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 
DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The P64 LED UV can be controlled via DMX-512 protocol. The P64 LED 
UV is a three channel DMX unit. The DMX address is set on the back 
panel of the P64 LED UV. Your unit and your DMX controller require a 
standard 3-pin XLR connector for data input and 
data output (Figure 1). If you are making your own 
cables,  be  sure  to  use  standard  two  conductor 
shielded cable (This cable may be purchased at 
almost  all  pro  sound  and  lighting  stores).  Your 
cables  should  be  made  with  a  male  and  female 
XLR  connector  on  either  end  of  the  cable.  Also 
remember that DMX cable must be daisy chained 
and can not be split.

©American DJ®  -  www.americandj.com  - P64 LED UV Instruction Manual Page 5

  P64 LED UV                                                              Set Up

©

American DJ Supply

®

  -  www.americandj.com  - P64 LED UV Instruction Manual Page 6

Figure 1

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

 P64 LED UV 

 

                                            Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When longer  runs of  cable are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Отзывы: