American DJ MB DMX Скачать руководство пользователя страница 4

DMX IN

DMX OUT

DMX IN

DMX OUT

©American DJ®  -  www.americandj.com  - MB DMX™ Instruction Manual Page 7

©American DJ®  -  www.americandj.com  - MB DMX™ Instruction Manual Page 8

  MB DMX™  

 

 

 

 

 

Linking

Figure 2

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special  Note: 

Line  Termination. 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  ZDMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

 MB DMX™  

 

 

 

 

 

 Set Up

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT

OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Notice:

 

Be sure to follow figure three when making your own cables. 

Do not use the ground lug on the XLR connector. Do not connect the 
cable’s shield conductor to the ground lug or allow the shield conduc-
tor  to  come  in  contact  with  the  XLR’s  outer  casing.  Grounding  the 
shield could cause a short circuit and erratic behavior.

5-Pin XLR DMX Connectors: 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 
may be implemented in a 3-pin XLR DMX line. When inserting stan-
dard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

Master/Slave Linking:

For  a  more  dramatic  effect,  link  several  MB  DMX™  together.  Your 
fixture  comes  with  built-in  programs.  These  programs  are  designed 
to work with up to 4 units when daisy-chained together in a master-
slave configuration. Any unit can function as either a “Master Unit” or 
a “Slave Unit.” Link the units together using standard DMX cable as 
described on pages 6 and 7.  

To next MB DMX™ if applicable

Optional MINI/C blackout controller

Optional MINI/C:

The  optional  MINI/C  controller 
allows  all  units  linked  together 
to  blackout.  This  unit  will  only 
blackout the fixtures and will not 
change  or  select  different  pro-
grams. 

Blackout Button

30 Foot Extension Cable

Blackout Indicator

Содержание MB DMX

Страница 1: ...Unpacking 3 Introduction 3 Customer Support 3 Safety Precautions 4 Features 5 Registration 5 Set Up DMX Linking 6 Data Cable Requirements 6 Termination 7 5 Pin Conversion 7 Linking 8 Operating Modes S...

Страница 2: ...ons carefully to familiarize your self with the basic operations of this unit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this ma...

Страница 3: ...ess is set on the side panel using the dipswitches Your unit and your DMX controller require a standard 3 pin XLR connector for data input and data output Figure 1 If you are making your own cables be...

Страница 4: ...dvisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 ON Figure 4 Notice Be sure to follow figure three when making your own cables Do n...

Страница 5: ...X control mode This function will allow you to control each unit s individual traits with a standard DMX 512 controller such as the American DJ and LSC DMX Operator or Show Designer Stand Alone Operat...

Страница 6: ...the various DMX fixture traits A list of the traits is located on page 13 4 This will allow you to create your own programs 5 When using a DMX controller and setting up for DMX operation follow the D...

Страница 7: ...SPEED5 2 5 rpm SPEED6 3 rpm SPEED7 4 rpm Dipswitch 9 Control Rotation Direction On CW Rotation Off CCW Rotation Dipswitch 10 Controls Master Slave Operation On Master Off Slave Note Dipswitch 10 must...

Страница 8: ...i ability of the product if the product has been repaired or serviced by anyone other than the American DJ factory unless prior written authorization was issued to purchaser by American DJ if the prod...

Отзывы: