background image

©

American DJ Supply

®

  -  www.americandj.com  - Fusion Scan 250™ User Manual Page 11

The Fusion Scan 250™ may be controlled by a wide range of control-
lers; ie. Show Designer™, DMX Operator,™ Scene Setter™ or by the 
DJ MINI/C basic controller.

MINI/C features:

  

Fusion Scan 250™  

 

 

       Optional Remote

The  MINI/C  controller  may  be  purchased  separately  allowing  you  to 
control  the  main  unit,  and  any  others  connected  to  it,  while  it  is  in 
stand alone mode. You can set the unit to blackout. If you have more 
than one unit, make sure the remote control is plugged into the first 
unit in the daisy chain. The remote control will not have any effect if 
the unit is in DMX mode. When the unit is in blackout mode, the light 
will come on next to the blackout button.  

30 ft. cable

Stand by (Black out)

©

American DJ Supply

®

  -  www.americandj.com  - Fusion Scan 250™ User Manual Page 12

  

Fusion Scan 250™  

 

             Lamp Replacement   

Lamp  Replacement:   

Caution!  Never  open  the  unit  when  in  use.  

Always  disconnect  the  main  power  before  attempting  to  replace  the 
lamp. 

1.  Be sure to follow the proper procedures when handling halogen      
     bulbs.
2.  Lamp replacement has been made simple by incorporating the use  
     of a removable lamp tray and thumb screws.
3.  Loosen the thumb screw on rear cover.
4.  Remove the tray.
5.  Remove and replace the bulb.
6.  Reassemble.

Remember to always replace with the exact same type lamp and 
fuse,  unless  otherwise  specified  by  an  authorized  American  DJ 
service technician. 

  

Fusion Scan 250™  

 

 

                    Focusing

1.  To focus a Fusion Scan 250,™ it is best to first turn down the    
 

music sensitivity knob to its minimum position.

2.  Loosen the thumb screw on the front of the unit that hold the lens  
 

in place.

3.  Adjust the focus by manually moving the lens up and down.
4.  Tighten the thumb screw after you achieve your desired focus.

The Fusion Scan 250

 carries a one year (365 days) limited warranty. 

We  recommend  you  fill  out  the  enclosed  warranty  card  to  validate 
your purchase. All returned service items whether under warranty or 
not,  must  be  freight  pre-paid  and  accompany  a  return  authorization 
(R.A.) number. If the unit is under warranty, you must provide a copy 
of your proof of purchase invoice. Please contact American DJ

®

 cus-

tomer support for a R.A. number.

  

Fusion Scan 250™  

 

           Product Registration

Содержание Fusion Scan 250

Страница 1: ...any comments or suggestions Toll free customer service hours are Monday through Friday 9 00 a m to 5 30 p m Pacific Standard Time Voice 800 322 6337 Fax 323 582 2941 E mail support americandj com To purchase parts online visit http parts americandj com Warning To prevent or reduce the risk of electrical shock or fire do not expose this unit to rain or moisture Caution There are no user serviceable...

Страница 2: ...ANGER VISIBLE LASER RADIATION AVOID DIRECT EYE EXPOSURE LASER DIODE WAVELENGTH 635 650 nm Max Output 4 9mW Class IIIa Laser Product American DJ Supply www americandj com Fusion Scan 250 User Manual Page 4 Fusion Scan 250 Safety Precautions The fixture should be serviced by qualified service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been...

Страница 3: ...s 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first reading and understanding all safety and technical data in this manual Always set up and install all laser effects so that all laser light is at least 3 meters 9 8 feet above the floor on which people can stand American DJ Supply ww...

Страница 4: ... controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compli ant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are con...

Страница 5: ...Ground Special Note Line Termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behavior A terminator is a 90 120 ohm 1 4 watt resistor which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a cable ter...

Страница 6: ... exact pattern Note Only one fixture may use the master units dipswitch settings 5 After all the units settings have been set and are plugged in adjust the sensitivity knob on the bottom of the master unit to American DJ Supply www americandj com Fusion Scan 250 User Manual Page 10 Fusion Scan 250 Operating Instructions make them react to sound 7 You can also use the optional MINI C Remote Control...

Страница 7: ...o follow the proper procedures when handling halogen bulbs 2 Lamp replacement has been made simple by incorporating the use of a removable lamp tray and thumb screws 3 Loosen the thumb screw on rear cover 4 Remove the tray 5 Remove and replace the bulb 6 Reassemble Remember to always replace with the exact same type lamp and fuse unless otherwise specified by an authorized American DJ service tech...

Страница 8: ...such as blackout sweeps 2 Be sure the audio sensitivity knob is turn in the full clockwise position maximum sensitivity If problems are not resolved Contact your American DJ customer support for possible service options Fusion Scan 250 Trouble Shooting American DJ Supply www americandj com Fusion Scan 250 User Manual Page 14 Due to fog residue smoke and dust cleaning the internal and exter nal opt...

Страница 9: ... 250 DMX Traits Channel Value Function 1 0 255 PAN 2 0 255 TILT 3 COLORS 0 28 LAMP OFF 29 57 WHITE 58 86 RED 87 115 BLUE 116 144 GREEN 145 173 YELLOW 174 202 ORANGE 203 231 PINK 232 255 PURPLE 4 GOBO 0 7 SPOT 8 21 SPOT SHAKE 22 29 GOBO 1 30 43 GOBO 1 SHAKE 44 51 GOBO 2 52 65 GOBO 2 SHAKE 66 73 GOBO 3 74 87 GOBO 3 SHAKE 88 95 GOBO 4 96 109 GOBO 4 SHAKE 110 117 GOBO 5 118 131 GOBO 5 SHAKE 132 139 GO...

Страница 10: ... because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above American DJ Inc will replace defective parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in mat...