background image

ADJ Products, LLC  -  www.adj.com  - Eco UV Bar DMX User Manual Page 7

ADJ Products, LLC  -  www.adj.com  - Eco UV Bar DMX User Manual Page 6

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-

nect the cable’s shield conductor to the ground lug or allow the shield 

conductor to come in contact with the XLR’s outer casing. Grounding 

the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer runs  of  cable are 

used, you may need to use a terminator on the last unit to avoid erratic 

behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-

nected between pins 2 and 3 of a male XLR connector (DATA + and 

DATA -). This unit is inserted in the female XLR connector of the last 

unit in your daisy chain to terminate the line. Using a cable terminator 

(ADJ part number Z-DMX/T) will decrease the possibilities of erratic 

behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XLR 

connectors for DATA transmission in place of 3-pin. 5-pin XLR fixtures 

may be implemented in a 3-pin XLR DMX line. When inserting standard 

5-pin XLR connectors in to a 3-pin line a cable adaptor must be used, 

these adaptors are readily available at most electric stores. The chart 

below details a proper cable conversion.

Conductor

5-Pin XLR Male (In)

3-Pin XLR Female (Out)

Pin 1

Do Not Use

Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  Eco UV Bar DMX                                              DMX Set Up

  Eco UV Bar DMX                             Operating Instructions

LED Display On/Off:

To set the LED display to turn off after 10 seconds, press the MODE but-

ton until “dS-x” is displayed. 

“X” represents either “1” or “2”.

 Press the 

UP or DOWN buttons so that “dS-2” is displayed. Now the display will 

disappear after 10s. Press any button to turn the display on again. Be 

advised though that the display will turn off automatically after 10 sec-

onds. 

“dS-1” = LED display on at all times.

“dS-2” = LED display shuts off after 10 seconds.

DMX Mode:

Operating through a DMX controller gives the user the freedom to create 

their own programs tailored to their own individual needs. The Eco UV 

Bar DMX has 3 DMX Channels.

1.  This function will allow you to control each individual fixture’s traits  

  with a standard DMX 512 controller.

2.  To run your fixture in DMX mode press the MODE button until    

  “1XXX” is displayed. “XXX” represents the current displayed ad-

  dress. Use the UP or DOWN buttons to select your desired DMX   

 address. 

3. 

Please see page 9 for the DMX values and traits.

4.   After you have set your desired DMX address 

plug in the fixture via  

    the XLR connections to any standard DMX controller.

Strobe Mode:

1.   Plug the fixture in and press the MODE button until “2-XX” is dis-

    played. “XX” represents a number between 1-20.

2.   The strobe speed can be adjusted between 1 (slowest) to 20 (fastest).

3.   Use the UP and DOWN buttons to adjust the speed to your desire.

Output Intensity:

1.   Plug the fixture in and press the MODE button until “UXXX” is dis-

    played. “XXX” represents a number between 000-255.

2.   The output intensity can be adjusted between 000 (off) to 255 (bright- 

    est).

3.   Use the UP and DOWN buttons to adjust the output intensity to your  

   desire.

Delay:

1.   Plug the fixture in and press the MODE button until “dr-X” is dis-

    played. “X” represents a number between 0-4.

Отзывы: