ADJ Products, LLC - www.adj.com - Dotz Matrix User Manual Page 11
Dotz Matrix System Menu
2. 1 of 5 dimming curve settins will be displayed: Standard, Stage,
TV, Architectural, or Theatre. Use the UP and DOWM buttons to
select your desired dimming curve and press ENTER to confirm.
ADJ Products, LLC - www.adj.com - Dotz Matrix User Manual Page 10
Universal DMX Control:
This function allows you to use a Elation®
universal DMX-512 controller to control the chases and patterns,
dimmer and strobe. A DMX controller allows you to create unique
programs tailored to your individual needs. The Dotz Matrix has 5
DMX channel modes; a 3 Channel Mode, 6 Channel Mode, 7 Channel
Mode, 48 Channel Mode, & 52 Channel Mode. To select your channel
mode see page 8.
1. This function will allow you to control each individual fixture’s
traits with a standard DMX 512 controller such as the
Elation® Show Designer™ or the Elation® DMX Operator.™
2. To run your fixture in DMX mode, follow directions on page 8 to
set your DMX address and DMX Channel mode.
3. Plug in the fixture via the XLR connections to any standard DMX
controller.
4. For longer cable runs (more than a 100 feet) use a terminator on
the last fixture.
Dotz Matrix Universal DMX Control
Master-Slave Operation:
This function will allow you to link up to 16
units together and operate without a controller. The units will be sound
activated. In Master-Slave operation one unit will act as the controlling
unit and the others will react to the controlling units programs. Any unit
can act as a Master or as a Slave.
1. Using approved DMX data cables, daisy chain your units together
via the XLR connector on the rear of the units. Remember the
Male XLR connector is the input and the Female XLR connector is
the output. The first unit in the chain (master) will use the female
XLR connector only - The last unit in the chain will use the male
XLR connector only. For longer cable runs we suggest a termina-
tor at the last fixture.
2. On the Master unit set your desired operating mode.
3. On the slave units press the MODE button until “Slave Mode” is
displayed.
4. The slave units will now follow the Master unit.
Dotz Matrix Master-Slave Configuration
Dotz Matrix Photometrics
0
0
1
2
3
4
5
1
1
2
2
3
4
Intensity(LUX)
Beam opening(m)
3
4
60
80
2.65
3.65
3.75
5.33
4.90
7.00
6.05
8.70
Beam angle 60°
Field angle 80°
60° Diameter(m)
80° Diameter(m)
Red LEDs
Green LEDs
Blue LEDs
Full LEDs
2130
3050
4730
10140
681
793
1405
2630
302
398
716
1360
197
246
368
730
136
173
224
476