background image

American DJ

®

  -  www.americandj.com  - Comscan LED Instruction Manual Page 10

American DJ

®

  -  www.americandj.com  - Comscan LED Instruction Manual Page 9

 Comscan LED 

 

 

 

             System Menu

System Menu: When making adjustments you can press 
ENTER to confirm your setup or you can wait 8 seconds for 
automatic setup. To exit without making any adjustments 
press the MENU button. 

ADDR -

 

DMX Address Setting

.

1. Tap the either the MENU, UP, or DOWN buttons until “

ADDR

” 

is displayed, press ENTER.
2. The current address will now be displayed and flashing. 
Press the UP or DOWN buttons to find your desired address. 
Press ENTER to set your desired DMX address. 

SLMD -

 This will let you set unit as a master or slave in a 

master/slave configuration.

1. Tap the MENU button until “

SLMD

” is displayed, press 

ENTER. Either “

SL 1

” or “

SL 2

” will be displayed.

2. Tap the UP or DOWN buttons until your desired setting is 
displayed, press ENTER to confim.

NOTE:

 In a Master/Slave configuration you can set one fixture 

to Master and then set the next fixture to “

SL 2

”, the fixtures will 

now have contrast movement to each other. 

SHND: SH

 

0

 

-

 

12

 

- Show modes 0-12 (Factory programs).

 

You can run show mode with sound active mode off or on.

1.  Tap  the  MENU  button  until  “

SHND

”  is  displayed,  press 

ENTER.
2.  “

S

X

”  will  now  be  displayed,  “X”  representing  a  number 

between 0-12. Programs 1-12 are factory programs, while “

S

0

” is random mode. Press the UP or DOWN buttons to find your 

desired  show  and  press  the  ENTER,  then  press  and  hold  the 
MENU button for at least 3 seconds to confirm. 

SOUN -

 Sound Active mode.

1. Tap the MENU button until “

SOUN

” is displayed, press 

ENTER.
2. The display will show either “

ON” 

or

 “OFF

”. Press the UP or 

DOWN buttons to select “

ON

” to activate sound active mode, or 

OFF

” to deactivate sound active mode.

3. Press ENTER to confirm.

BLND -

 Blackout or Stand by mode.

1. Tap the MENU button until “

BLND

” is displayed, press 

ENTER. Either Yes or No will be displayed. 
2. To activate Blackout tap the UP or DOWN buttons until “Yes” 
is displayed, press ENTER to confim. The fixture will now be in 
Blackout mode. To deactivate Blackout mode, select “No” and 
press Enter.

LED -

 With this function you can have the LED display 

turn off after 10 seconds.

1. Tap the MENU button until “

LED

” is displayed, press ENTER.

2. The display will show either “

ON” 

or

 “OFF

”. Press the UP or 

DOWN buttons to select “

ON

” to keep the LED display on at 

all times, or “

OFF

” to switch to have the LED display switch off 

after 10 seconds.
3. Press ENTER to confirm.

DISP

 

This function will reverse the display 180º.

1. Tap the MENU button until “

DISP

” is displayed, press ENTER.

2. Press ENTER to “flip” the display. Press ENTER to “flip” it 
again. Press ENTER when you have made your desired setup.

 Comscan LED 

 

 

 

             System Menu

Содержание Comscan LED

Страница 1: ...is a five channel DMX intelligent LED scanner The Comscan LED can operate as a stand alone fixture or in a Master Slave configuration The Comscan LED has three oper ating modes sound active mode show...

Страница 2: ...personnel when A Objects have fallen or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a m...

Страница 3: ...peration The Comscan LED can be controlled via DMX 512 pro tocol The Comscan LED is a five channel DMX unit The DMX address is set electronically using the controls on the rear panel of the unit Your...

Страница 4: ...a 3 pin DMX line When inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a prope...

Страница 5: ...ow be displayed X representing a number between 0 12 Programs 1 12 are factory programs while Sh 0 is random mode Press the UP or DOWN buttons to find your desired show and press the ENTER then press...

Страница 6: ...is function will run a self test program 1 Tap the MENU button until TEST is displayed press ENTER 2 The fixture will now run a self test TEMP With this function you can check the temperature of the f...

Страница 7: ...ol This function allows you to use a Elation universal DMX 512 controller to control the chases and patterns dimmer and strobe A DMX controller allows you to create unique programs tailored to your in...

Страница 8: ...a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all parts completely before plugging the unit back in Comscan LED F...

Страница 9: ...e and repair labor by reason of defects in material or workmanship The sole responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof...

Страница 10: ...5 DMX Channels Sound Active Yes Working Position Any Safe Secure Position Operating Temperature Do Not Operate in Temperatures above 104 Fahrenheit Warranty 3 Year 1095 days American DJ www americandj...

Отзывы: