![American Changer AC 500 CoinCo BA30BAB Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/american-changer/ac-500-coinco-ba30bab/ac-500-coinco-ba30bab_operation-manual_2922512016.webp)
16
PROBLEM:
I.
The bill validator red status
LED flashes a “5” error
code.
(AC500’S ONLY!)
II.
The bill validator red status
LED flashes a “6 or 7” error
code.
(AC500’S ONLY!)
J.
The bill validators red status
LED is on steady but it still
will not accept the bill.
(AC500’S ONLY!)
K.
The red “empty” LED on
the outside of the changer is
on, the red status LED on
the main logic board is
flickering on and off
normally, and the hopper is
full of coins.
FOR TECHNICAL SERVICE OR
TO OBTAIN A RETURN
AUTHORIZATION NUMBER
CALL (888) 741-9840
SOLUTION:
1. Clean the validator optic LED’s. (See pg. 12)
2.
Ensure that all the wire harness plugs are plugged firmly into their
white female sockets.
3.
Turn to the back page of this manual and check for a Coin Acceptors
branch in your area to repair your bill validator.
1.
Take the bill stacker off the bill validator. Cycle the power on / off
using the switch on the main logic board and coast the silver push bar
so that it stops in its fully extended position. Blow out the area behind
the push bar with high pressure or canned air. Concentrate on the
encoder wheel in the area top center behind the push bar.
2.
Turn to the back page of this manual and check for a Coin Acceptors
branch in your area to repair your bill validator.
1.
Pull out the lower housing, see page 5, and look for something
obstructing the bill path. (I.e. gum; paper tickets, coins, etc.)
2.
Look inside the Plexiglas case on the side of the bill validator. Ensure
that all the wire harness plugs are plugged firmly into their white
female sockets.
1.
Ensure the hopper is not out of coins. (There should be enough coins
in the hopper to cover the gold low-level contact plates. These plates
are located at the bottom of the hopper where you pour the coins.)
2.
Check the hopper wire harness that extends from the back of the plate
that the hopper slides in and out on for chipped pieces or other
damage. (Pay close attention to pins # 2 & 7.)
3.
Clean the gold contact plates with steel wool.
4.
Replace the hopper.
5.
Replace the hopper wire harness.
ANY REPAIR RETURNED WITHOUT A RETURN
AUTH. # WILL BE REFUSED!
TROUBLESHOOTING GUIDE
TO USE THE TROUBLESHOOTING GUIDE, MATCH UP THE PROBLEM, THEN FOLLOW THE
SOLUTION SUGGESTIONS. After every step re-try operating the changer to see if the problem has been