©American Audio® - www.americanaudio.com - vX Series™ power Amplifier user manual page 14
aMpLIFIer passWorD/LoCK FeatUre:
use this feature to lock in your settings and prevent accidental adjustments.
THE INITIAL USER PASSWORD IS 88. With user password, you can enter and change the setting of the amp. If the wrong password
is entered, “PASSWORD: Error” will be displayed. You can change the initial password to set your own password.
the deFaULt PaSSWord IS 86548.
With this password you can change the setting of the amp regardless to whatever password is
set. If the wrong password is entered, “PASS WORD: Error” will be displayed. If you cannot remember your password, use the default
password.
hoW to Set/Change yoUr PaSSWord:
1. make all your desired settings and adjustments.
2. Press the MENU button, until the screen displays “NEW PASS Wd: 0 1 2 3 4 5 6 7 8 9”.
3. Next, press the UP or DOWN buttons to move the cursor right or left, to your desired number. Press ENTER to select your desired
number.
4. Your password must be 5 numbers long. The new password will be saved by the amp automatically, and the LCD will return back to
the regular screen displaying the working mode and temperature.
hoW to Change PaSSWord StatUS:
1. choose your desired password.
2. Press the MENU button, until “MENU Pass Word SEL” is displayed.
3. Press the ENTER button to enter the password status menu. The screen should display “Pass Word SEL”, with either “Pass Word
ON” or “Pass Word OFF” also displayed. Using the UP or DOWN buttons you can chose between either ON or OFF. Find your
desired setting and press enTer to make your selection.
4. If the Password Status is set to “OFF”, you do not need to enter your password to make adjustments to the amp settings.
if the password Status is set to “on”, you will have to enter your password to make adjustmetns to the amp settings.