12
The Premium Series Programmable Control MODEL APVC
MODEL APVC
The Optional Premium Programmable Control
is
fully digital and allows you to program when and how much fresh
air enters your home.
Key Features
• 24 / 7 programmable ventilation
• 4 programmable events per day
• 5 Speed Fan setting
• Electronic Dehumidistat
• Four Selectable Modes of Operation
20 min. ON / 40 min. off
20 min. ON / 40 min. recirculate *
Continuous Ventilation
Continuous Recirculation *
• 20 / 40 /60 High Speed override timer
•
Service/Maintenance Reminder display
• Backlit LCD screen is easy to read
Setting Date & Time
1. Press and release MODE Select Button until "TIME" and
"SET" appear on the screen. Press SET Button.
2. The letter for the day of the week flashes. SCROLL (using
Up/Down Arrows) to the correct day of the week. Press SET
Button.
3. The hour and "AM" or "PM" flashes. SCROLL to the correct
hour using the Increase or Decrease Buttons. Press SET
button.
4. The minutes will flash. SCROLL to the correct minute. Press
SET button to complete entry.
Programming Your Control
1. Press and release the MODE Button until "PROGRAM SET"
appears. Press SET Button.
2. Weekday letters (MTWTF) will flash. Press SET Button.
3. "WAKE" flashes. Press SET Button.
4. "AM" or "PM" flashes. SCROLL to desired time (in 20
minute intervals). Press SET Button.
5. "FAN" flashes. SCROLL to desired fan speed (0-5). Press SET
Button.
6. "OFF" flashes. SCROLL to desired operation mode (VENT,
20/40, 20/40 RECIRC*, RECIRC*, OFF). Press SET Button
two times. (Refer to "Selecting the Best Mode of Operation" in
this manual for a description of operational modes.)
7. "LEAVE" flashes. Repeat steps 4 to 6 to program up to 4
events per day.
8. “SS” (Saturday & Sunday) Flashes repeat steps 3 to 7.
9. (Optional) M flashes. This can be used to program individual
days of the week. Scroll to day and repeat steps 3 to 7.
* RECIRC not available on all models.
Running the Programmed Setting
Once the programming has been completed, activate the program.
• Press the MODE Button until "PROGRAM" and "RUN" are
indicated.
Setting the Dehumidistat
Refer to "How the Dehumidistat Works" in this manual before
setting the Dehumidistat.
1. Press and release the MODE Button until "RH" and a number
flashes. SCROLL using the Increase or Decrease Buttons to
desired number (RH Set Point). Press the MODE Button to
exit. Refer to "How the Dehumidistat Works" in this manual
for a description of the functionality of the Dehumidistat.
2. Press the MODE Button to return to operational features.
Manually Setting the Control
1. Press and release MODE until "MANUAL" and "RUN" are
indicated. Press SET.
2. SCROLL to select desired fan speed (0-5). Press SET.
3. Use SCROLL to select the desired operational mode (VENT,
20/40, 20/40 RECIRC*, RECIRC*). Press SET.
4. The control will remain in the "MANUAL RUN" position until
you change back to "PROGRAM RUN" (refer to "Running the
Programmed Setting").
20/40/60 Minute High Speed Override Button
This function temporarily initiates high speed ventilation for 20,
40 or 60 minutes. Press FAN button once for 20, twice for 40 and
three times for 60 minutes.
Service Indicator
After 4 months, a ‘SERVICE’ indicator will appear. Refer to
"Maintenance Routine for your HRV/ERV" in this manual.
To reset the service indicator:
• Press and release the Increase/Decrease buttons simultaneously.
The “SERVICE” icons will flash for 5 seconds..
• Press SET within the 5 seconds and the service indicator resets.
Instruction card
Fan Speed
Indicator
20/40/60 Minute
High Speed
Override Button
Mode Select
Button
ON/OFF
Button
High Speed
Override
Timer
Indicator
Humidity
Indicator
Increase
Button
Set button
Decrease
Button
Service
Indicator
Mode
Indicator
Date & Time
Daytime
Event
Program
Indicator
Connects to 3 wire 20 gauge
low voltage wire
Only one main control can be installed on your
system.