background image

As illustrated, start the full function test by using the 
magnet found on the back side of the test tab to touch the 
Test Area. Just like the Battery Test, the strobe LED will flash 
once and the device will beep once when the test magnet 
approaches the Test Area. Hold the magnet next to the Test 
Area for 3 additional seconds in which a second audible 
beep indicates the unit is in Full Function Test. The battery 
LED and GPS LED will commence to flash every 3 seconds 
to indicate the battery status and GPS locating status:

6.2 Full Function Test

The green battery LED indicates that the battery is ok. If the 
battery LED flashes red light, this indicates low battery power 
and the battery needs to be replaced.
The green GPS LED next to the antenna indicates that GPS fix is 
achieved, the red GPS LED means that no GPS position is 
obtained. 

EC Declaration of Conformity

The symbol above means that your product and/or its battery shall be disposed 
of separately from household waste according to local laws and regulations. 

End of Life Statement 

Battery 

The lithium-ion battery in TB-520 should be replaced only by AMEC or an AMEC 
authorized service provider, and must be recycled or disposed of separately 
from household waste. Never attempt to replace the TB-520 battery yourself.
Do not recharge, puncture, deform, short-circuit the lithium batteries contained 
in product or put it in fire.
The small lithium metal batteries contained in the device can normally be 
carried on passenger aircraft in carry-on baggage as a personal item. Always 
check with air carrier for any additional restrictions.

• 

• 

• 

Hereby Alltek Marine Electronics Co declares that this device is in compliance with 
the essential requirements R&TTE Directive. All materials, components and 
products supplied of the device are in full compliance with RoHS & Weee 
directives. A copy of the Declaration of Conformity can be obtained online from 

www.alltekmarine.com

RF Exposure warning

Warning: This device generates and radiates RF electromagnetic energy and 
requires a Maximum Permissible Exposure of 20cm by operation.

The high beam LED will flash once and the beeper will beep 
once signifying the device has entered into battery life test 
mode. The green flash indicates that the battery is ok. If 
your device flashes red light, this indicates low battery 
power and the battery needs to be replaced. The device will 
flash 3 times and beep once again to end the test.

Note: 

1) You can interrupt the test mode any time by pull off the activation tab and then 

insert the tab subsequently. Please notice that under test mode, the device will 
not transmit distress message also when the activation tab is removed. Hence 
there is no risk of activating the alarm transmission when the user pulls the 
activation tab off to abort the test mode.

2) The MOB test message generated by a full function test will appear on all chart 

plotters with AIS within range in the form of a SRM (Safe Related Message).  The 
message is “MOB TEST“ with the device´s MMSI number as sender´s identity. 

7. Specification

Note: Specifications are subject to change without prior notice.

VHF PERFORMANCE

Frequency 

                            

 

                         

Data Rate 

                         

Tx Power 

                         

Bandwidth 

                         

Modulation                           
Range 

                         

AIS Message Type              
 

                        

 

                                                   

AIS 1, 161.975MHz
AIS 2, 162.025 MHz
9,600bps
2W (1W EIRP)
25 KHz
GMSK
4nm typical with receiver antenna > 5m above sea level
Message 1 (UID, GPS position, SOG, COG) 
Message 14 (MOB ACTIVE or MOB TEST) 

GPS PERFORMANCE

Receiving Channels               
Frequency 

                         

Tracking Sensitivity               
Reacquisition                          
Position Accuracy                  

 

           

50
L1, 1575.42 MHz
(-)159 dBm
(-)159 dBm

 2.0 m SBAS 

 2.5 m Autonomous   

BATTERY

Type  
Operating Time 
Storage (battery life) 

Primary Lithium (not rechargeable)
36 hours at -10°C, typical
5 years, replacement due after emergency use

ENVIRONMENTAL

Operating Temperature 
Storage Temperature 
Waterproof
Immersion Depth
Compass Safe Distance

-20°C~55°C
-30°C~70°C
IP68 
100m
0.8m

GENERAL/PHYSICAL

Model No. 

 

Size  
Weight  

TB-520D
129x52x40mm (L*W*D)
160 g (main unit only)

APPLICABLE STANDARDS

IEC 60945 
IEC 61108-1

EN 303098- 1 V1.2.1
EN 303098- 2 V1.2.1

Note:

1) 

2) 

3) 

4) 

5) 

6)

7)

When activated, the high beam LED on device will flash SOS signal in Morse code 
format every minute.
Upon activation the device will transmit MOB ACTIVE signal every minute with 
Lat/Lon position information. In case the GPS location cannot be updated due to 
weather conditions, the last obtained Lat/Log GPS position will be sent.
As the device is still new on the market, not all chart plotters with AIS show the 
correct       icon as recommended by the IMO. As a minimum, they will show the 
same icon as used for other craft - normally an        . The MMSI number dedicated 
for AIS MOB begins always with 972 which will differentiate AIS MOB from 
normal AIS targets.  Please contact with your plotter manufacturer how they 
display       on screen when there are further questions.
Ensure the TB-520D remains out of the water, as water will inhibit the GPS 
receiver and may cause difficulties obtaining GPS coordinates.
Ensure that the blue area marked “GPS Area” is not shielded or covered in any 
way and always has a clear view of the sky. It is recommended that the Short Test 
is performed monthly. Return the TB-520D to a service centre for battery 
replacement if battery level is low. 
Confirm that the battery expiry date shown is in date for the duration of 
intended use.
This product emits low levels of radio frequency energy during operation. Avoid 
handling the antenna once activated.

5. Turning off your TB-520D

The device is equipped with self test capability to perform 2 different tests to 
ensure the beacon is working perfectly. The first is a battery life test to check 
the beacon’s battery power. The second test is a GPS self test that includes 
GPS activation and live test message transmission.

6. Testing your TB-520D

5.1 Closing the red antenna cap

Align the red antenna cap with the unit, longer side facing the front and the 
shorter side facing the back. Push the red antenna cap all the way until the 
antenna cap clip pass the wedge.

As soon as GPS fix is achieved, the device will start sending MOB test messages, 
which will be displayed with a       icon on all AIS systems within range. The Full 
Function Test will be completed with a beep, after 8 bursts of test messages are 
successfully sent. When no valid GPS data is obtained within 5 minutes, the Full 
Function Test is regarded as failed and will be ended with a beep as well. 
In case of a failed Full Function Test, check and make sure that the antenna is 
pointing towards the sky and the “GPS Area” marked on the device is not 
obstructed by hand or other objects. When the Full Function Test fails a second 
time, return the device to your service center. 

- 7 -

- 8 -

- 5 -

- 6 -

- 9 -

- 10 -

6.1 Battery Life Test

Start the battery life test by using the magnet found on 
the back side of the test tab to touch the Test Area for one 
full second.

Insert the activation tab back in the unit and the transmission will be ceased.  
Put the antenna back to its original position by wrapping around the unit, as 
well as, the antenna cap.

S/N(UNIQUE ID):

972160001

JUL 2015

BATTERY EXPIRY:

S/N(UNIQUE ID):

972160001

JUL 2015

BATTERY EXPIRY:

AIS Man Overboard Beacon

S/N(UNIQUE ID

):

972160001

JUL 2015

BATTERY EXPIRY:

Отзывы: