No data is being received by chart plotter, why?
Please check that the power supply is connected correctly at CAMINO-108.
Please check that the power supply is 12V or 24V with sufficient current
capacity (no less than 2A).
Please make sure that the connections between CAMINO-108 to the chart
plotter are correct.
My MMSI is being received by other vessels but my vessel name is
not shown on their chart plotter or PC, why?
Older software and AIS displays may not be fully compatible with Class B
transponders. In some of these cases, older equipments might only have Class
B vessel show up on their displays with just MMSI number without the vessel
name. This is usually due to the receiving device not knowing how to process
the Message 24 static data from Class B transponders. Please contact the chart
plotter maker and ask for software upgrades (for these older chart plotters) to
resolve this issue.
The Red Error LED indication at CAMINO-108 is illuminated, why?
The unit may not have a valid MMSI. Please check if the AIS transponder is
correctly entered with a valid MMSI.
Please make sure that both VHF and GPS antennas and their cables are
working properly and not damaged.
Why is the Wi-Fi signal weak and how can I improve it?
The router is too far from the client devices. To improve the Wi-Fi signal
strength reallocated your Transponder to a more central location.
Содержание Camino-108
Страница 1: ......
Страница 2: ......
Страница 9: ...9 CAMINO 108 CAMINO 108W Front Back Front Back...
Страница 11: ...11 1 3 External Connections...
Страница 18: ...18 Figure 1 Mounting the transponder...
Страница 33: ...33 Figure 9 Static Data Setting...
Страница 43: ...43 Figure 15 Join an existing Wi Fi network...
Страница 50: ...50 5 2 Dimensions GPS antenna is an optional item...
Страница 64: ...64 Serial port number...
Страница 65: ......