LCD Display

1. Unit display
2. Pressure display
3. Function select display
4. Working indicator

Function and Operation

This device includes the OPS  

(Over Pressure Setting) function used to

 

inflate and seat t

i

res on the rim.

 

Operation

SET OPS

KPA
BAR
PSI
KGF

2

.

 

Set OPS (Over Pressure Setting)

2

.1.   Press (SET) once, (SET) and (OPS)

will be shown on the LCD screen, 
(OPS) will be flashing.

2

.2.  Press (+) or (-) to choose the 

OPS value.

2

.3.  Press (SET) to confirm. If 

OPS value is not zero, (OPS) will 
be displayed at the LCD screen.

3

.

 

Manual inflation

If t

i

re pressure is lower than 3 p.s.i. or 0.2

 

bar, the device will not start automatically. 

3

.1. Press (SET) t

wice

, the 

current pressure will be shown 
on the LCD screen.

   

3

.2

.

 

 

Press (+) to start manually.

 

 

4

.

 

Set programmable buttons

(P1) initial value is 15 p.s.i. /1 bar, (P2) 
initial value is 30 p.s.i. /2.1 bar. The preset 
pressure value can be reset by the user, 
setting it here will save it for following 
usage. But it reverts to the initial value 
after a unit set change.

1. Press (P1) or (P2), (P1) preset value or

(P2) preset value will be shown on the
LCD screen.

2. Press (+) or (-) to choose preset

pressure value.

3. Press (SET) to confirm.

1.

 

Unit select

Device has four units can be chosen by the 

user which is kpa-psi-bar-kg/cm2.

Unit set here will become default unit for 

following usage, do not need to set unit 

each time.

1.1.   Press (SET), (SET) will be shown 

         on the LCD screen, and the unit  

         will be flashing.

1.2.   Press  (+)  or  (-)  to  choose  the 

         

 

unit.

1.3.   Press (SET) to confirm.

Содержание Fasy-Flate 24868

Страница 1: ...Part No 24868 PSI...

Страница 2: ...from damp heat dust oils do not remove tear or amend any parts of the manual for any reason It must be made available to the operator and to maintenance personnel also to ensure staff training In cas...

Страница 3: ...Table of Contents Components List 4 Features 5 Introduction 5 Control Panel 5 6 Function and Operation 6 7 Troubleshooting 8 Maintenance 9 Specifications 10 Calibration Certificate 11 Instruction Manu...

Страница 4: ...4 Components List Inflator Hose 5 ft PSI 1 4 BSP to 1 4 NPT adaptor Hot shoes and charger AU UK EURO USA Instruction manual Part No 24868 PSI Illustrative purposes only...

Страница 5: ...rmation is for your safety and to prevent damage to this product The hazard or unsafe practice could result in minor injury WARNING The hazard or unsafe practice could result in severe injury or death...

Страница 6: ...T twice the current pressure will be shown on the LCD screen 3 2 Press to start manually 4 Set programmable buttons P1 initial value is 15 p s i 1 bar P2 initial value is 30 p s i 2 1 bar The preset p...

Страница 7: ...t saving any selection 3 When OPS function is selected the device will inflate to target pressure plus the OPS value first then deflate to tire pressure desired for example A final target of 32 p s i...

Страница 8: ...ected Check the hose connection make sure that no air leaks Tire pressure is below 3 p s i Manual inflation Err1 Pressure sensor broken Power off change pressure sensor Err2 Unstable pressure faulty h...

Страница 9: ...ne check of the air connections is suggested In the event that maintenance is required it should be carried out by qualified personal Note This unit must be used with clean dry air Therefore an air fi...

Страница 10: ...rking Temperature 10 50 C 14 122 F Auto Off 90 seconds Hose Length 5 ft 1 5 m Inlet Size 1 4 NPT Chuck Type Clip on Chuck Style Single straight Reader Unit Digital display with audible warning Dimensi...

Страница 11: ...uipment with an accuracy that is traceable to International Standards according to 86 217 EEC ALLOWABLE TOLERANCE p s i 1 2 up to and including 58 p s i 2 3 between 58 and 145 p s i inclusive 3 6 grea...

Страница 12: ...Product No 24868...

Отзывы: