Light
path
diagnostics
LEDs
The
following
table
describes
the
LEDs
on
the
light
path
diagnostics
panel
and
on
the
system
board,
and
suggested
actions
to
correct
the
detected
problems.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Lit
light
path
diagnostics
LED
Description
Action
None
An
error
has
occurred
and
cannot
be
isolated,
or
the
service
processor
has
failed.
An
error
has
occurred
that
is
not
represented
by
a
light
path
diagnostics
LED.
Check
the
BMC
log
for
more
information
about
the
error.
DIMM
x
error
A
memory
error
occurred.
1.
Make
sure
that
the
DIMM
indicated
by
the
lit
LED
is
supported.
2.
Reseat
the
DIMM
indicated
by
the
lit
LED.
3.
Replace
the
DIMM
indicated
by
the
lit
LED.
Note:
Multiple
DIMM
LEDs
do
not
necessarily
indicate
multiple
DIMM
failures.
If
more
than
one
DIMM
LED
is
lit,
reseat
or
replace
one
DIMM
at
a
time
until
the
error
goes
away.
Refer
to
the
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
or
Problem
Determination
and
Service
Guide
for
your
BladeCenter
unit
type
for
further
isolation.
Microprocessor
x
error
The
microprocessor
has
failed.
1.
Make
sure
that
the
microprocessor
indicated
by
the
lit
LED
is
installed
correctly.
(See
for
installation
instructions.)
2.
(Trained
service
technician
only)
Replace
the
microprocessor
indicated
by
the
lit
LED.
MIS
(Microprocessor
mismatch)
The
microprocessors
do
not
match.
Make
sure
that
microprocessors
1
and
2
are
identical
(number
of
cores,
cache
size
and
type,
clock
speed,
internal
and
external
clock
frequencies);
also,
see
NMI
(NMI
error)
The
system
board
has
failed.
1.
Replace
the
blade
server
cover,
reinsert
the
blade
server
in
the
BladeCenter
unit,
and
then
restart
the
blade
server.
2.
Check
the
BMC
log
for
information
about
the
error.
(Trained
service
technician
only)
If
the
problem
remains,
replace
the
system
board
assembly.
S
BRD
(System
board
error)
The
system
board
has
failed
1.
Replace
the
blade
server
cover,
reinsert
the
blade
server
in
the
BladeCenter
unit,
and
then
restart
the
server.
2.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
42
AMD
Opteron
LS20
Type
8850
for
IBM
BladeCenter:
Problem
Determination
and
Service
Guide
Содержание Opteron LS20
Страница 1: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 2: ......
Страница 3: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 14: ...xii AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 70: ...56 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 102: ...88 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 112: ...98 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Страница 113: ......
Страница 114: ...Part Number 24R9677 Printed in USA 1P P N 24R9677...