HIGH WALL AIR CONDITIONER
GB
User manual and installation guide
HW
9EZ
12EZ
18EZ
Страница 1: ...HIGH WALL AIR CONDITIONER GB User manual and installation guide HW 9EZ 12EZ 18EZ...
Страница 2: ...ectrical installation have it checked and if necessary modified by a qualified electrician The air conditioner is safe However as with other electrical appliances use it with care Keep the remote cont...
Страница 3: ...This gas absorbs the warmth of the air in the room the cooled air is blown back into the room and the heat absorbed by the refrigerant gas is led to the compressor A fan 3 draws the air a over the fi...
Страница 4: ...s are not applicable to this air conditioner Using the remote control The remote control signal has a range of up to 8 m Point the remote control at the receiver in the indoor unit A beep confirms tha...
Страница 5: ...of the display indicates the selected mode Auto 1 Press the MODE BUTTON 6 until the symbol appears next to AUTO 2 The temperature is automatically set to 25 C and can not be adjusted 3 Use the FAN SP...
Страница 6: ...nd side of the display next to TURBO Press this button again to cancel the turbo operation and return to the other air flow rates Timer button timed switching off 1 Press the TIMER BUTTON 8 to enter t...
Страница 7: ...resulting smaller reduction in room temperature Normal living spaces require about 100 W per square metre of floor surface In strong sunlight or if other sources of heat are present this may be as muc...
Страница 8: ...very small amount of neutral detergent Rinse well and allow to dry completely not in direct sunlight or near a source of heat 3 Keep the grid panel open and reinstall the filter s Press the panel shu...
Страница 9: ...m the outlet even when switched off the air conditioner will consume about 5 W and take the batteries out the remote control clean the indoor and outdoor unit clean the filters as well END OF PERIOD O...
Страница 10: ...H DBQBDJUZ PG 8 JT CFTU QMBDFE JO B N SPPN PSUI GBDJOH BOZ XJOEPXT VDI TVOTIJOF 4PVUI GBDJOH INSTALLATION GUIDE In case of a non quick coupling unit make sure to have the professional after sales serv...
Страница 11: ...sockets during work out of doors Check electrical equipment for any damage Never use equipment with a switch that does not work Be careful when working on steps ladders and scaffolding Be extra caref...
Страница 12: ...y modified by a qualified electrician Ensure you have a well lit and a work area clear of clutter a well thought out and pre arranged work plan sound tools and reliable implements protection safety go...
Страница 13: ...le 5 10 mm lower Figure 4 so that the condensed water can smoothly flow out Cut the wall penetrating pipe to proper length according to the thickness of the wall i e 3 5 mm longer than the wall thickn...
Страница 14: ...sunshine but has good ventilation no restriction to the air flow where noises will not affect neighbouring places away from areas where generation ingress stagnant or leakage of inflammable gases mig...
Страница 15: ...For pipes vacuuming see Exhaust air paragraph Connect the indoor connections suitable for quick coupler Be aware that it is possible to connect the connectors only in one way Follow the procedure belo...
Страница 16: ...ect the quick cable coupler from the indoor unit with the one from the outdoor unit Figure 11 bottom 3 Use a pressing plate to fix the wires firmly and replace the cover Note Incorrectly connected wir...
Страница 17: ...utdoor unit Air filter Room temperature detecting probe Air inlet side and rear Air discharge Drain tube Air flow direction adjusting Air outlet Refrigerant piping connection Electric connection Emerg...
Страница 18: ...Dehumidification max L 24h 17 24 31 Air flow at high fan speed m3 h 500 600 729 Refrigerant R410A Refrigerant load g 760 1080 1500 Room size up to m2 27 35 47 Fan speeds 3 Thermostat C 16 32 Timer h...
Страница 19: ...be protected by a 13 amp fuse in the plug The appliance is supplied with a moulded 13 amp 3 pin mains plug fitted with a 13 amp fuse Should the fuse require replacement it must be replaced with a fus...
Страница 20: ...at West Road Brentford Middlesex TW8 9ER United Kingdom Tel 44 20 8560 4141 Fax 44 20 8232 8814 Email amcoruk amcorgroup com USA Amcor Inc 685A Gotham Parkway Carlstadt New Jersey 07072 United States...