TROUBLE SHOOTING

7

If the product is used according to this manual you should enjoy trouble free use. 

In case of difficulty please check the following points and refer to the Amcor Help line 

should you need further assistance? 

Problem

Check

Remedy

Product does not start

Is the “power” light on? 

Make sure the unit is plugged in to a 
live mains socket.

Is the “water full” light on?

Make sure the container is empty of 
water and fitted properly in position. 
Make sure the float in the water 
container is attached and not broken

Water is leaking 
outside of the water 
tank in continuous 
drainage mode?

Is the continuous drainage 
funnel selector properly 
positioned?

Ensure that the drainage funnel 
selector is pulled forward and clicked 
into position. 
To return the unit to water tank use, 
push the funnel selector back into 
the unit until it clicks and re-insert the 
stopper.
Check there are no blockages to the 
flow out of the funnel.

Has the unit been running 
in cold temperatures under 
5ºC? 

Switch off for 2 hours to defrost in 
an area where a water leak will not 
cause damage and only run the unit 
in a heated room above 5ºC

Has the container been 
removed for emptying 
straight after the unit was 
running?

Wait a few minutes to allow possible 
ice and condensation within the 
unit to flow into the container after 
switching off the unit.

Reduced water 
extraction

Is the humidity knob 3 turned 
too far anticlockwise turning 
the compressor off when the 
humidity is still higher than 
required?

Turn the humidistat knob (3 on 
controls page) clockwise to a make 
the dehumidifier extract water down 
to a lower relative humidity or fully 
clockwise to the continuous setting.

Is the air already relatively 
dry?

Water extraction rate is reduced 
when the humidity level is reduced 
e.g. when the air temperature is low.

Is the unit running in a cold 
room?
Generally the colder the 
air the less moisture will be 
removed.

Ensure that the unit is operating in a 
heated room above 5ºC. Switch off 
for 2 hours to defrost and restart with 
the heater switched on.

Are the filters blocked?

Washable air filter may need 
cleaning.
Activated carbon filter (where fitted) 
may need replacing.

Not collecting water

Is the “water full” light on?

Make sure the container is empty of 
water and fitted properly in position.

Содержание HD220H

Страница 1: ...H 320H DEHUMIDIFIER INSTRUCTION MANUAL IT IS IMPORTANT THAT YOU READ THESE INSTRUCTIONS BEFORE USING YOUR NEW DEHUMIDIFIER AND WE STRONGLY RECOMMEND THAT YOUR KEEP THEM IN A SAFE PLACE FOR FUTURE REFE...

Страница 2: ...ty environment Your Amcor dehumidi er draws in air through the lower front panel onto a re frigerated cold grill As the air in the room passes over the cold surface mois ture condenses and collects in...

Страница 3: ...s and windows should be kept closed when the dehumidi er is operating When positioning your Amcor dehumidi er ensure that it is placed on a level surface clear of any obstacle that may limit the air m...

Страница 4: ...high fan speed quicker moisture removal HEATER Unit works with the 800W HEATER ONLY when the humidistat 3 is turned fully clockwise For the DEHUMIDIFIER and 800W HEATER to WORK TOGETHER when dehumidi...

Страница 5: ...ainage hose as follows Remove the water container from the unit Pull the funnel selector to the continuous drainage position A as shown in g 1 It should be pulled forward and clicked into position Thi...

Страница 6: ...ciency dust lter to purify the air It is recommended to clean the washable air lter at regular intervals depending upon how frequently the unit is used at least once a month To do this rst remove the...

Страница 7: ...a water leak will not cause damage and only run the unit in a heated room above 5 C Has the container been removed for emptying straight after the unit was running Wait a few minutes to allow possibl...

Страница 8: ...www amcorgroup com HD220H 320H GB 04 2005...