Air flow

On the moment the air conditioner is connected to the mains, the louvres open and 
close and stay closed.
 •  When the ON-button is pressed, the louvres open to maximum and return to an 

angle of 75° above the upper plane of the louvres housing.

 •  Press the  -button, the louvres will swing continuously up and down between 

30° and 80° above the upper plane of the louvres housing. 

 •  By pressing the  -button again the movement will stop and the louvres remain 

in that position. The direction of the air flow is then constant.

 •  When the OFF-button is pressed, the louvres close.
This way of directing the air flow is particularly convenient when using the remote 
control: a user friendly approach to your comfort.
In order to direct the air flow to a lower angle, raise the louvres housing by pulling it 
up only by the centre of its back rim.

Sleep mode

The sleep mode function adjusts the set temperature of the unit to the thermal 
needs of the body falling asleep as follow:
 •  Default fan speed: LOW
 •  Press the  -button to operate the sleep mode. Press the  -button again in order 

to cancel the sleep mode.

  The set temperature will increase 1°C after 1 hour and a further 1°C after 2 hours.
 •  No FAN mode under SLEEP mode operation.

Dehumidification

If the unit will be used mainly as a dehumidifier just let the warm air return in the 
room. Continuous drainage (see separate chapter) is then necessary and more 
efficient.

Air outlet up, 

louvres opened

Air outlet down, 

louvres closed

Raising the 
louvres housing.

GB

Содержание CPLM 12KE-B-410

Страница 1: ...PORTABLE AIR CONDITIONER GB Portable air conditioner CPLM 9KE B 410 12KE B 410 15KE B 410...

Страница 2: ...d for indoor operation Rating This unit must be connected to a 220 240 V 50 Hz earthed outlet The installation must be in accordance with regulations of the country where the unit is used If you are i...

Страница 3: ...o could result in a loss of warranty WARNING Do not use your air conditioner under the following conditions Close to a naked flame Inside unit exposed to the weather outdoors Near water If the power c...

Страница 4: ...st hose Water container Remote control with LCD PARTS 1 2 3 4 10 6 5 8 7 9 3 1 Air outlet 2 Control panel 3 Carrying handle 4 Caster wheels 5 Grill housing 6 Upper air inlet 7 Exhaust air outlet 8 Low...

Страница 5: ...5 CONTROL PANEL Mode Increase Decrease Swing ON OFF Fan Timer Sleep mode Sensor remote control Clock Cooling Sleep Timer mode Temperature Fan Timer settings GB...

Страница 6: ...se to the unit by turning it clockwise at least 5 turns Similarly connect the hose to the slide bar connector as far as possible Place the telescopic slide bar in the open window or door and adjust th...

Страница 7: ...Pressing the button to switch the operating mode between cooling and fan only Fan speed If you prefer a constant fan speed instead of the auto fan speed press the button successively the fan speed ic...

Страница 8: ...e ON time until 24 00 The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes The unit will operate daily according to the timer setting Repeated ON and O...

Страница 9: ...remote control a user friendly approach to your comfort In order to direct the air flow to a lower angle raise the louvres housing by pulling it up only by the centre of its back rim Sleep mode The s...

Страница 10: ...lmost identical to the operation by the control panel The only exception is the clock function Instead of the button for setting the actual time and for programming the timer there are 3 push buttons...

Страница 11: ...ed every 3 months Filter installation Slide out the filter frame from the unit Separate the filter fixer from the filter frame see fig 1 Remove the active carbon filter black from its plastic bag Inse...

Страница 12: ...plug into the wall socket and switch the unit on The warning signal should be off NOTE When the air conditioner is in use under normal circumstances the condensed water will evaporate and then be dis...

Страница 13: ...not work The overheat protection is probably activated Wait 3 minutes until the temperature has decreased then turn on the unit again The remote control does not function Distance too great Make sure...

Страница 14: ...class IP 21 Refrigerant type R410A Refrigerant load g 420 500 630 Dimensions w x h x d mm 500 x 840 x 415 Net weight kg 33 1 34 3 39 3 CPLM 9KE B 410 series can be connected only to a supply with syst...

Страница 15: ...re Great West Road Brentford Middlesex TW8 9ER United Kingdom Tel 44 20 8560 4141 Fax 44 20 8232 8814 Email amcoruk amcorgroup com USA Amcor Inc 685A Gotham Parkway Carlstadt New Yersey 07072 United S...

Отзывы: