Amcor ALD-1 2 Скачать руководство пользователя страница 4

5

Control Panel

Setting Mode/Function

Press the MODE button to select the required working mode: Automatic, Cooling, Fan or Heating (Heating is only
available for ALD-12,000EH). The green indicator illustrating your selected mode lights up.  It is recommended to
select Cooling or Heating mode and set your desired temperature, as the Auto mode has a preset temperature (please
see below) that cannot be changed.

The indicators of the functions in progress come on at the same time, e.g. Cool and Lo = Cooling mode with Low fan speed.

Auto Mode

When this mode is selected, the unit is preset to the following temperature settings and unit will only start to:
• Cool when room temperature is higher than 75ºF
• Heat when room temperature is lower than 68ºF (ALD-12,000EH only)

If room temperature is between 68ºF and 75ºF, unit will stay in Fan mode.  Again, when in Auto Mode, the temperature
settings cannot be changed.

Setting the Temperature in Cooling or Heating Mode

T

he display window’s default is to display the ambient room temperature.  The green indicator light under RT is on.

(RT = Room Temperature)

To set your desired temperature, press the Temperature up or down buttons (ranging from 64ºF to 90ºF).  Each press
will increase or decrease your set temperature by 1ºF.  When pressing the temperature up or down buttons, the
window will change to display your set temperature. At this time, the green indicator will light under ST (Set
Temperature).  Once the temperature up or down buttons is released, the window will return to displaying the
ambient temperature after a second.

Note:

  When unit is in the following modes:   Auto, Cool, or Heat - the compressor will cool/heat the room to reach

the set temperature.  Once the ambient temperature has reached the set temperature, the compressor will stop and
unit will run in Fan mode.  To conserve energy, the compressor will not start immediately after a couple degrees
increase or decrease, but will wait for a 5ºF allowance.  For example:

In Cooling Mode with a set temperature of 70ºF

When compressor first stops after reaching 70ºF, unit will auto-switch to Fan.
Compressor will start cooling again when ambient temperature increases to 75ºF or above.

In Heating Mode with a set temperature of 72ºF

When compressor first stops after reaching 72ºF, unit will auto-switch to Fan.
Compressor will start heating again when ambient temperature drops to 67ºF or below.

In Auto Mode (with preset temperature of 68ºF for heat and 75ºF for cool)

Compressor will start cooling again when ambient temperature reaches above 80ºF or will start heating when
ambient temperature drops below 63ºF.

Parts

1. Control Panel

2. Cooling Air Outlet

3. Handle

4. Castors

5. Air Filter

6. Air Inlet

7.  Exhaust Air Outlet

8. Cord Hanger

9.  Water Stopper (Rubber Plug Inside)

10

11

12

13

14

15

16

Accessories

10. Adaptor - for insertion over the 

hose and into the back of the
air conditioner

11. Exhaust Hose

12. Foam Strip - for filling the open 

window space and with a hole for
connection to the exhaust hose

13.  Foam Strip - for filling the open 

window space

14.  Round Connector - to be used 

between hose and window kit or 
between hose and wall

15.  Cap for Round Connector

16. Remote Control

(Electronic control models only)

8

Not available

on all units

Fan Only

Cool

Auto

Set Temp.

Room

Temp.

Low Fan

Not available on all units

High

Fan

Timer

Power

Mode:

AC or Fan

Temp. Up

Temp. Down

Fan Speed:

High / Low

On / Off

Timer

Operation - Electronic Control Models

Содержание ALD-1 2

Страница 1: ...d or altered in any way that adversely affected its performance or reliability To obtain warranty service the defective product or part must be shipped or delivered to Amcor s authorized service cente...

Страница 2: ...or doors open Are there too many people in the room Is there something in the room producing lots of heat Is the room temperature within 5 of the selected temperature The unit seems to do nothing Is...

Страница 3: ...a Container Use a Shallow Container or Dish 1 Turn off the unit 2 Position a flat container or dish under the drain hole Do not allow the water to drip continuously into the container as it might easi...

Страница 4: ...eat the compressor will cool heat the room to reach the set temperature Once the ambient temperature has reached the set temperature the compressor will stop and unit will run in Fan mode To conserve...

Страница 5: ...is shorter than 24 please measure and cut the foam strip with the pre cut hole to size If your window s height or width is longer than 24 but shorter than 48 please attach the two strips together by u...

Страница 6: ...ARE NOT FOLLOWED Operation Electronic Control Models Setting The Fan Speed Press the SPEED button to choose the fan speed you require high or low The indicator of high or low fan will light up at the...

Страница 7: ...t to maximum cooling and high speed fan initially then adjust the unit to a comfortable setting NOTE It is recommended to turn on the air conditioner when the room temperature is around 75 F Do not wa...

Страница 8: ...13...

Отзывы: