background image

4

9

Before Use

Turn the roller on the
air vent to control
the airflow direction from
the vertical louvers.

Move the air vent
directly to adjust the
airflow direction
from the horizontal
louvers.

Regulating the Airflow Direction

Operation

Setting The Fan Speed

Press the SPEED button to choose the fan speed you require, high or low.
The indicator of high or low fan will light up at the same time.

If the unit is in AUTO mode, it will select the fan speed automatically according to the
ambient temperature (the related indicators, cool, fan or heat will light up), at this time the
fan speed switch is invalid.

Setting the Timer

Press the TIMER button to set the operating hours you desire (1 to 12 hours, the timer
indicator will light up).  When the set time has elapsed, the machine will turn off
automatically.  The display window will show the hour(s) you set as you press the TIMER button.
If the timer button is not pressed, the unit will work continuously.

By pressing the timer button but without turning on the unit, you can PRE-SET the time for
the machine to work.  For example, if you press the timer to ‘2’,
the unit will come on automatically after 2 hours.

All the above functions can also be performed with the supplied remote
control.  This remote control requires 2 AAA batteries to operate.

IMPORTANT!

•  The compressor will start approximately 3 minutes after the unit is turned on (this will 

help prolong the life of the compressor).  After switching the unit off, please wait at least
3 minutes before turning the unit back on.

• The cooling system will switch off if the room temperature is lower than set.  The fan, however, keeps 

working at the set level.  If the ambient temperature rises above the chosen tempe/-5

°

F,

the cooling will resume.

•  In heating mode, the compressor will switch off if the room temperature is HIGHER than the one set 

(the fan keeps working at the set level).  When the room temperature drops 5

°

F below the chosen 

temperature, heating will resume.

•  This machine is equipped with an ANTI-FROST function.  Sometimes, while using the heating function 

during low temperatures, the heating will stop for a while to melt the internal frost.  When this occurs,
wait for heating to resume.

•  As you switch on the heating, the fan will stop for 15-20 seconds prior to the unit starting.

Important!

• Leave the unit in an upright position for at least 2 hours before use.

•  Always place the unit on an even surface.

•  The power cord has a built-in L.C.D.I. (Leakage, Current, Detection, Interruption) circuit

breaker for added safety.  If the power supply is interrupted, please press the reset
button to reconnect the unit to the power source.  The green light should be on.

•  Make sure the unit is connected to a correctly grounded power supply.

• For proper operation, the unit must be vented to the outside.

• Do not cover or obstruct the appliance inlet or outlet grilles.

•  To avoid the risk of shock, the product should never be used in bathrooms, shower rooms 

or in any other steamy or wet areas.

• Always transport the unit in an upright position.

• Do not sit or stand on the unit.

• Do not place objects on the unit.

•  Do not touch the unit with wet/damp hands or when standing barefoot.

• Drainage of the water container is required before moving the unit or

putting it into storage.

• If the electric socket is different from the plug provided, have a professionally qualified 

electrician replace the outlet with a suitable one.  Avoid the use of adaptor plugs, multiple 
sockets and/or extension cords; if their use is necessary, ensure that they conform to the 
current safety regulations.

• Do not pull the power cord or place it near a source of heat; always unroll it completely

to avoid the possibility of dangerous overheating.

• If the power cord is damaged, it must be replaced by a qualified person.

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE
INSTRUCTIONS ARE NOT FOLLOWED.

Содержание 000E AL-10

Страница 1: ...which it was not designed or 4 repaired or altered in any way that adversely affected its performance or reliability To obtain warranty service the defective product or part must be shipped or deliver...

Страница 2: ...and windows are open The filter is dirty Clean or replace filter Air inlet or air Remove blockage outlet is blocked Room temperature lower Lower temperature selected than the selected value The overhe...

Страница 3: ...ool the unit and make it run more efficiently This is a feature not found in most Portable Air Conditioners If the unit is operated inVERY HUMID air water will collect in the container inside the unit...

Страница 4: ...will cool heat the room to reach the set temperature Once the ambient temperature has reached the set temperature the compressor will stop and unit will run in Fan mode To conserve energy the compress...

Страница 5: ...2 Attach Slide Bar Connector Round Connector to the other end of the Hose by extending hose at least 6 Then tighten Hose by turning the Round Connector clockwise 3 Place Adjustable Slide Bar in the wi...

Страница 6: ...the one set the fan keeps working at the set level When the room temperature drops 5 F below the chosen temperature heating will resume This machine is equipped with an ANTI FROST function Sometimes w...

Страница 7: ...ngThe Power Cord When the unit is not in use please store the power cord away as shown Thank You Thank you for choosing the portable air conditioner from AMCOR a leading brand in indoor air treatment...

Страница 8: ...13...

Отзывы: