SMD-23 Integrated Stepper Drive & Motor
20 Gear Drive, Plymouth Industrial Park, Terryville, CT 06786
page: 11
Tel: (860) 585-1254 Fax: (860) 584-1973 Web: www.amci.com
ADV ANC ED
MIC RO CON T RO L S INC.
Changing the SMD23 Configuration Settings (continued)
Procedure: (continued)
6. Select the Port menu and choose the COM port that the cable is connected to:
7. Turn on the power supply to the drive.
8. Press the Connect button. For a few seconds the TX and the RX lights can change
their color to green to inform that the program is establishing the communication.
Once they settle to red, the communication is established. The current settings of the
drive will be displayed (RESOLUTION, IDLE and CURRENT), together with the
identification of the Drive. The motor will be disabled until the next power up.
For example:
9. If a change to a setting is required, the new setting is selected from the appropriate
field.
By pressing the Defaults button, the default settings will appear:
•
RESOLUTION: 2000 steps/revolution
•
IDLE: 20% (Motor Current when motor is idle)
•
CURRENT: 80% (Operating Current)
The firmware
version
Status
display