INSTALLING THE SD17060E
4
39
I/O Wiring (continued)
Output Wiring
The SD17060E output is an optically isolated
transistor that is capable of driving a typical
PLC input. Both ends are uncommitted, so it
can be wired as a sinking or sourcing output.
Electrical Specifications
R
LIMIT
A resistor may be needed to limit the current
through the output. The value, and power rating
of the resistor is dependent on the value of Vdc,
the voltage drop across the input, and the current
requirements of the input.
Encoder Wiring
The figure below shows how to wire a 5Vdc differential encoder to the SD17060E.
h
The ±A channel must be wired to Input 1 for proper operation
h
The ±B channel must be wired to Input 2 for proper operation
h
The ±Z channel is optional. If used, it must be wired into Input 3. The Z channel is only used when
homing the SD17060E.
Figure 4.7 Sample Encoder Wiring
SD17060B
Output
OUTPUT–
R
LIMIT
*
V
DC
+5 to +24V
SD17060E Output - Sinking Connection
PLC Input
Shielded, Twisted
Pair Cable
Ic
SD17060E
Output
OUTPUT–
R
LIMIT
*
V
DC
+5 to +24V
SD17060E Output - Sourcing Connection
PLC Input
Shielded, Twisted
Pair Cable
Ic
Figure 4.6 Output Wiring
V
DC
max:
V
CE
SAT
:
30Vdc
1Vdc @ 20 mA
Power Dissipation: 20 mW max.
Ic max: 20 mA
SAT
RED
BLK
Shield
WHT
YEL
GRN
BLU
ORN
BRN
AMCI Encoder
(Optional on all AMCI
dual shaft stepper motors.)
RED
BLK
Shield
WHT
BLK
GRN
BLK
BLU
BLK
RED
BLK
WHT
BLK
GRN
BLK
BLU
BLK
+A
–A
+B
–B
+Z
–Z
+5Vdc Isolated
Power Supply
INPUT1 –
INPUT2 –
INPUT3 –
Belden 8304 or equ. Suggested
GROUND THE SHIELD OF THE ENCODER CABLE
1) Ground only one end of shield
2) Shield is usually grounded where the signal is generated. If a good quality
earth ground connection is not available at the encoder, the shield can be
grounded to the same Ground Bus as the SD17060E.
SD17060E