AMCI ME15 Скачать руководство пользователя страница 1

        

                                                   

 

 

20 Gear Drive, Plymouth Industrial Park, Terryville, CT 06786                                                      page: 1 
Tel: (860) 585-1254     Fax: (860) 584-1973     Web: www.amci.com 
 

ME15 Magnetic Encoder Manual 

 

Revision 1.1 

Product Overview 

 

The ME15 Magnetic Encoder is the newest addition to AMCI’s Encoder product line. The encoder is designed for 
lower resolution and lower cost applications and provides 10 bits of resolution. The user has a choice either a SSI or 0 
to 20mA, 4 to 20mA, 0 to 5V or 0 to 10V analog output. ME15’s small size, high reliability, IP67 protection rating and 
low cost, make it an ideal replacement for potentiometers and small industrial encoders. Sturdy machined housing and 
a high resistance to shock and vibration also make these encoders better able to withstand difficult environmental 
conditions. 
 
ME15 has two major components: A small diametrically polarized magnet and a custom ASIC which contains an array 
of Hall sensors that generate a voltage when exposed to a magnetic flux field. The ASIC detects the change in 
magnetic flux distribution as the magnet rotates above it delivers a voltage representing its angular position. The ASIC 
cancels magnetic interference permitting it to operate in areas of high external fields. The encoder’s electronics 
features a programmable device for converting the signals to a SSI-compatible bit stream. 
 
The encoder is housed in an IP67 Size15 (1.5” dia) servo mount body with two options for shaft sizes - 1/4” and 6mm, 
and two options for connections – through a 7-pin connector or built-in cable with flying leads of various lengths. 
 

 

 

 

 

  

 

 
 
 
 
 
 
 
 
 
 

Содержание ME15

Страница 1: ...d vibration also make these encoders better able to withstand difficult environmental conditions ME15 has two major components A small diametrically polarized magnet and a custom ASIC which contains a...

Страница 2: ...der normal use in materials and workmanship for a period of 18 months Within this warranty period AMCI shall at its option repair or replace free of charge any equipment covered by this warranty which...

Страница 3: ...ME15 Magnetic Encoder Manual Revision 1 1 Table of Contents Product Overview 1 Specifications 4 ME15 SSI Option 5 ME15 SSI Output Ordering Guide 9 ME15 Analog Output Option 10 Analog Voltage Output 1...

Страница 4: ...n max 25 C with standard shaft seal 0 2 oz in max 25 C no shaft seal Shaft Loading 10 lbs radial 5 lbs axial maximum shaft loading Bearing life 2x109 revolutions minimum at maximum shaft load Electric...

Страница 5: ...tied to the DC Return When M15 works as Multiplexing SSI device Enable line determines whether particular M15 s input output driver is enabled Enable Input low or disabled Enable Input high Only one...

Страница 6: ...falling edge of the next CLK cycle DO valid t is time between rising edge of CLK and data output valid Optionally if only absolute angular position data is needed then SSI clock with 10 pulses could...

Страница 7: ...ed at time Figure 4 Timing for ENn lines In a case that only one or a very few interrogations is needed during sampling time then the ENn and CLK signal synchronization is necessary and is outlined in...

Страница 8: ...Current 10 A 5VDC for both High and Low states Timing Characteristics SSI Option Cable Pin Assignment Mating connector sold separately AMCI MS 9 Binder 99 0426 00 08 Figure 6 Block Diagram SSI Output...

Страница 9: ...Seal Type S Shaft seal IP67 rating S Shaft seal Shaft Diameter 2 1 4 6 6mm 2 1 4 Shaft Output Type S SSI S SSI Output Scaling 1 binary 1 Binary Angular Range K 360 This is the only option available on...

Страница 10: ...factory preset 45 90 180 and 360 The analog output response is linear for the selected range For 45 and 90 modes the slope is mirrored at 180 For the 180 mode it has a step response at 270 This allow...

Страница 11: ...CCW increasing The Analog output version of the ME15 can be ordered to output its minimum to maximum output over the four Angular Ranges listed above However the next minimum to maximum cycle always...

Страница 12: ...r Supply 35mA Output Load 500Ohm max 4 20mA Option Current Consumption No Load and 24VDC Power Supply 35mA Output Load 500Ohm max Cable Pin Assignment Cable Style Color Connector Style Pin Signal Red...

Страница 13: ...4 Shaft Output Type V Analog Voltage C Analog Current V Analog Output Scaling If DuraCoder Type V 1 0 to 5Vdc 2 0 to 10Vdc If DuraCoder Type C 1 4 to 20mA 2 0 to 20mA V 2 0 to 10V C 1 4 to 20mA Angul...

Страница 14: ...20 Gear Drive Plymouth Industrial Park Terryville CT 06786 page 14 Tel 860 585 1254 Fax 860 584 1973 Web www amci com ME15 Magnetic Encoder Manual Revision 1 1 ME15 Mechanical Dimensions...

Страница 15: ...Web www amci com ME15 Magnetic Encoder Manual Revision 1 1 Manual Revision History Revision 0 0 was created 11 30 08 and was the initial release of the specifications Revision 1 0 was created on 1 30...

Отзывы: