![AMCI ANR2 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/amci/anr2/anr2_user-manual_2921188017.webp)
20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
O
PERATING
M
ODES
2
17
Power Up Behavior
When power is applied to the ANR2, it runs self checks and determines which modes have been successfully
completed by validating the data stored in its EEPROM. It sets status bits for each channel and then status
bits for the module. Its final act is to set the
Module Initialized
bit.
The
Module Initialized Bit
is only set when the ANR2 completes its power up sequence, and is
reset when the module accepts its first command. If this bit is set during normal operation,
then the module has experienced a hardware reset. This behavior can be caused by a tempo-
rary drop in input voltage or a surge of electrical noise that was induced into the module.
After power up, the ANR2 waits for the first command from the host controller before entering one of the
available modes. While waiting, the ANR2 only transmits status information. The words used to transmit
position data are set to zero.
For normal operation, you must issue a command to switch to Measurement Mode after every
power up. The ANR2 will not transmit position data to the host until this command is issued.
Switching Modes During Normal Operation
Figure 2.1 is a graphical representation of how the ANR2 allows you to switch between modes during normal
operation. You can jump from any mode to any
previous
mode, but, if parameter changes are saved while in
the new mode, you can only progress forward in the correct order after that.
Figure 2.1 Switching Between Modes
Calibration Mode
(Factory Set)
Configuration
Mode
Alignment
Mode
Measurement
Mode
The ANR2
will only set the
Calibration Mode bit on power up if the
factory settings have been corrupted.
The unit can be calibrated in the field,
but an accurate true RMS voltmeter is
required. Contact AMCI for assistance.
Содержание ANR2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A032...
Страница 14: ...INTRODUCTION TO THE ANR2 ADVANCED MICRO CONTROLS INC 1 14 Notes...
Страница 18: ...OPERATING MODES ADVANCED MICRO CONTROLS INC 2 18 Notes...
Страница 32: ...INSTALLING THE ANR2 ADVANCED MICRO CONTROLS INC 3 32 Notes...
Страница 36: ...AMCI NET CONFIGURATOR SOFTWARE ADVANCED MICRO CONTROLS INC 4 36 Notes...
Страница 48: ...CONFIGURATION MODE DATA FORMAT ADVANCED MICRO CONTROLS INC 6 48 Notes...
Страница 58: ...ALIGNMENT MODE DATA FORMAT ADVANCED MICRO CONTROLS INC 7 58 Notes...