![AMCC 3WARE 9500S Скачать руководство пользователя страница 100](http://html1.mh-extra.com/html/amcc/3ware-9500s/3ware-9500s_manual_2921146100.webp)
Chapter 3. Legacy CLI Syntax Reference
92
3ware 9000 Series Serial ATA Controller CLI Guide
info
cid
numdrives
This command reports the number of drives currently managed by the
specified controller
cid
. This report does not include units that have been
removed (placed off-line) with the maint remove command.
Also note that a physically removed disk is not detected unless I/O is
performed against the disk. See “info cid pid smart” on page 96 for a
workaround.
Example:
//localhost> info c0 numdrives
/c0 Number of Drives = 5
info
cid
unitstatus
This command presents status of units managed by the specified controller
cid
. It provides a list of units, their types, current status, percent complete if
rebuilding or verifying, size in GB, and the number of blocks of 512 bytes.
Example:
//localhost> info c0 unitstatus
Unit
UnitType Status %Cmpl
Stripe Size(GB)Cache AVerify OvrECC
----------------------------------------------------------
u0 RAID-5 VERIFYING 79 16K 819.446 ON OFF ON
info
cid
allunitstatus
This command presents a count of Total and NotOptimal units managed by
the specified controller
cid
. See “Info Commands” on page 87 for more
information on NotOptimal.
Example:
//localhost> info c0 allunitstatus
Total Units = 2
NotOptimal Units = 0