Serial port specification

Serial Port Hardware

RS-232

DB-9 Female

RS-485

Screw Terminal (4 connections)

RJ-45

Serial Port Communication Protocol

RS-485 asynchronous serial communication

Two Wire Half Duplex

9600 bps, 8 bits, 1 stop bit, no parity

no flow control

Command set specification

Command Format

All commands are in ASCII characters format except the first DEVICE ADDRESS
byte

DEVICE ADDRESS is an 8 bit hexadecimal character assigned by the 8 bit DIP
switch on this device

All commands begin with DEVICE ADDRESS and "*" (asterisk) character and end
with <CR> character (0D hexadecimal)

All commands RETURN with some feedback begin with DEVICE ADDRESS and "*"
(asterisk) character and and end with <CR> character (0D hexadecimal)

If a command produces an error or structured with incorrect syntax, the system
will return with "<ADDR>?<CR>" characters

Multiple commands require a delay of 500ms between commands

COMMAND

RETURN

XO-XOi-X86-DR-X86T MANUAL - RS485 Manual - v3.2

3

Содержание XOi

Страница 1: ...ource Audio Digital Home System XOi 4 Zone 4 Source Audio Digital Home System X86 6 Zone 8 Source Audio Video Digital Home System RS485 Manual RS485 RS232 Converter Module XO XOi X86 DR X86T MANUAL RS...

Страница 2: ...ber Range 4 Source Select Range 4 5 Standard Status Feedback Format 4 Status Feedback Conditions 4 Status Feedback Format 4 6 Command Reference 5 Zone Status 5 Tone Control Settings 5 Power OFF 5 Powe...

Страница 3: ...byte DEVICE ADDRESS is an 8 bit hexadecimal character assigned by the 8 bit DIP switch on this device All commands begin with DEVICE ADDRESS and asterisk character and end with CR character 0D hexade...

Страница 4: ...ormat Status Feedback Conditions Most commands send to the system will receive this type of Status Feedback unless specified explicitly Status Feedback Format RETURN ZNaa SRCbb GRPc VOL dd RETURN PARA...

Страница 5: ...nnSET00 COMMAND PARAMETERS nn Zone Number RETURN ZNaa BASSbb TREBbb GRPc RETURN PARAMETERS aa Zone Number bb EQ level 8 6 4 0 c 0 Group Mode Off 1 Group Mode On Power OFF ACTION Power OFF the given zo...

Страница 6: ...D ZNnnPWR02 COMMAND PARAMETERS nn Zone Number RETURN Standard Status Feedback Format RETURN PARAMETERS All Zones OFF ACTION Turn off ALL Zones COMMAND ZALLPWR00 COMMAND PARAMETERS RETURN ZALLOFF RETUR...

Страница 7: ...andard Status Feedback Format RETURN PARAMETERS Adjust Volume ACTION Adjust volume for the given zone COMMAND ZNnnVOLvv COMMAND PARAMETERS nn Zone Number vv Volume Level 00 62 where 62 mute RETURN Sta...

Страница 8: ...COMMAND PARAMETERS nn Zone Number RETURN Standard Status Feedback Format RETURN PARAMETERS Zone Mute ON ACTION Apply mute for the given zone and memorize the current volume COMMAND ZNnnMUT01 COMMAND P...

Страница 9: ...URN ZNaa BASSbb TREBbb GRPc RETURN PARAMETERS aa Zone Number bb EQ level 8 6 4 0 c 0 Group Mode Off 1 Group Mode On Group Mode OFF ACTION Disable Group Mode COMMAND ZALLGRP00 COMMAND PARAMETERS RETURN...

Отзывы: