background image

IA

AMC

X1616

16 ZONE 16 Local/8 Remote SOURCE DIGITAL H.O.M.E. SYSTEM

with Remote Sources

Содержание X1616

Страница 1: ...IA AMC X1616 16 ZONE 16 Local 8 Remote SOURCE DIGITAL H O M E SYSTEM with Remote Sources...

Страница 2: ......

Страница 3: ...d telephone mute system PDM1 option With RS232 to digital link with other systems option IR remote control receiver on 8 zones for controlling X1616 main unit and Remote Sources in other zones RCA 3 5...

Страница 4: ...All 4 Control In 5 Control Out 6 Mute 7 Status 8 Trigger 12VDC 9 RS232 Ethernet AMC Card 10 ID No Switch 11 L R Audio Input and Loop Connectors 12 Local Mix Remote Switch 13 Trim Input Sensitivity Ad...

Страница 5: ...igh with any zone ON and goes low when the last zone is turned OFF This is rather light current output and may not trip some external trigger inputs 8 12V DC This connector will give 12V DC 500mA powe...

Страница 6: ...these LEDs indicates when lit that its zone keypads are turned on The 16 square recesses are for putting labels of names of all zones jacks can either be controlled by the internal Volume Control of...

Страница 7: ...RCA Jack Inputs L R 3 5mm Mini Jack Inputs L R IR Output 3 5mm Mini Jack RJ45 L R Inputs and IR Output RJ45 to JK1 of XK1 via Cat 5 Cable 6 REMOTE SOURCE XS1 for Zone 1 to 8...

Страница 8: ...elect Amazon Alexa APP Touch 3 line icon on left upper corner on the page and select Settings Select Device or Set up a new device Select Bluetooth set Remote Bluetooth XS1bt to pairing mode Select Pa...

Страница 9: ...X1616 RJ45 Alexa Box AB01 for Zone 1 to 8 for Amazon Echo Dot RJ45 AB01 USB 5V 3 5mm Jack Audio DOT Mini USB 5V 3 5mm Jack Audio 8...

Страница 10: ...t is best that no single run of Cat 5 exceeds 250 feet The correct wiring scheme for the Cat 5 cable is standard EIA TIA 568A Properly terminating the Cat 5 cable is crucial for the operation of the s...

Страница 11: ...the RJ45 so all 8 conductors touch the end of the connector The insulation jacket should extend beyond the crimp point of the RJ45 Step5 Insert the RJ45 into the crimp tool receptacle and squeeze the...

Страница 12: ...porarily mute when the phone or doorbell rings 1 2 Doorbell This is an optional feature The back of PDM1 will accept up to two AC or DC voltages from two different doorbell chimes This connection is d...

Страница 13: ...ute Module Zone 1 Zone 2 Zone 9 Zone 10 Zone 9 16 Zone 1 8 Mobile Phone For Settings Only Dot Dot XS1bt XS1bt Remote Source Bluetooth Receiver Remote Source Bluetooth Receiver 12 WIRING DIAGRAM OF X16...

Страница 14: ...Zone 2 XS1 IR Zone 1 8 Doorbells 1 2 Rear Front Tel Lines AMC PDM1 Phone Doorbell Mute Module Zone 9 Zone 10 Zone 9 16 Mobile Phone For Settings Only Dot Dot 13 WIRING DIAGRAM OF X1616 DIGITAL H O M E...

Страница 15: ...urce IR POWER PRG RDM Dout Zone 2 XS1 Remote Source IR Zone 9 Zone 10 Zone 9 16 Zone 1 8 Doorbells 1 2 Rear Front Tel Lines AMC PDM1 Phone Doorbell Mute Module 14 WIRING DIAGRAM OF X1616 DIGITAL H O M...

Страница 16: ...out notice Total Zones 16 Zones Sources 16 Local 8 Remote Sources Sensitivity 0 60mV Phone input sensitivity AC25V AC100V 20Hz Doorbell input sensitivity AC DC 3 12V PHYSICAL X1616 Dimensions W x H x...

Страница 17: ...RS 232 PROTOCOL SPECIFICATIONS 16...

Страница 18: ...RS 232 PROTOCOL SPECIFICATIONS 17...

Страница 19: ...RS 232 PROTOCOL SPECIFICATIONS 18...

Страница 20: ...down load from Internet 2 Test Procedure a Load Tera Term Pro Version 2 3 or newer b Setting Port COM you will use Baud Rate 38400 Data 8 bit Parity none Stop 1 bit Flow Control none Transient delay 0...

Страница 21: ...0 8 4 C 2 A 6 E 1 0 or 1 0 1 0 UID 2 UID A 30 Zone 1 or 9 Source 14 0 0 1 1 0 0 0 0 0xCF30D8 ID 0 8 4 C 2 A 6 E 1 0 or 1 0 1 0 UID 2 UID A B0 Zone 1 or 9 Source 15 1 0 1 1 0 0 0 0 0x4FB0D8 ID 0 8 4 C...

Страница 22: ...1 0 or 1 0 0 0 UID 0 UID 8 A2 Zone 3 or 11 Mute 1 0 1 0 0 0 1 0 0x5DA2D8 ID 0 8 4 C 2 A 6 E 1 0 or 1 0 0 0 UID 0 UID 8 62 Zone 3 or 11 Unmute 0 1 1 0 0 0 1 0 0x9D62D8 ID 0 8 4 C 2 A 6 E 1 0 or 1 0 0 0...

Страница 23: ...8E Zone 4 or 12 Treble Up 1 0 0 0 1 1 1 0 0x718ED8 ID 0 8 4 C 2 A 6 E 1 0 or 1 0 0 0 UID 0 UID 8 4E Zone 4 or 12 Treble Down 0 1 0 0 1 1 1 0 0xB14ED8 ID 0 8 4 C 2 A 6 E 1 0 or 1 0 0 0 UID 0 UID 8 CE Z...

Страница 24: ...ID 0 8 4 C 2 A 6 E 1 0 or 1 0 0 0 UID 0 UID 8 35 Zone 6 or 14 Source 6 0 0 1 1 0 1 0 1 0xCA35D8 ID 0 8 4 C 2 A 6 E 1 0 or 1 0 0 0 UID 0 UID 8 B5 Zone 6 or 14 Source 7 1 0 1 1 0 1 0 1 0x4AB5D8 ID 0 8 4...

Страница 25: ...0 0 0 UID 0 UID 8 87 Zone 8 or 16 On 1 0 0 0 0 1 1 1 0x7887D8 ID 0 8 4 C 2 A 6 E 1 0 or 1 0 0 0 UID 0 UID 8 47 Zone 8 or 16 Off 0 1 0 0 0 1 1 1 0xB847D8 ID 0 8 4 C 2 A 6 E 1 0 or 1 0 0 0 UID 0 UID 8...

Страница 26: ...6 E 1 1 1 0 0 UID C D8 All Zones Source 4 1 1 0 1 1 0 0 0 0x27D8D8 ID 0 8 4 C 2 A 6 E 1 1 1 0 0 UID C 38 All Zones Source 5 0 0 1 1 1 0 0 0 0xC738D8 ID 0 8 4 C 2 A 6 E 1 1 1 0 0 UID C B8 All Zones Sou...

Страница 27: ...hat objects do not fall and liquids are not spilled into the enclosure through openings 15 SERVICING The user should not attempt to service the appliance beyond that described in the operating instruc...

Страница 28: ...PN 21R 4271 A 21R 4271 A 21R 4271 A...

Отзывы: