AMC SR136 Скачать руководство пользователя страница 1

 

 

 

The exclusive distributor of AMC products 

 

SR 136 

External optical and acoustic signaling device 
(DYNAMIC transducer 110dB; LED; metal 
enclosure; optional connection of the 12V/2,2Ah 
battery) 

 

CODE 

SR136 

 

In accordance with the  

EN 50131-4 standard

 

MANUAL  EN

 

 

Edition: 2 from 03.07.2014 

Supersedes: 1 from 10.02.2014 

 

 

1. Introduction 

 

The external optical and acoustic signaling  device SR136 is designed for Intrusion Detection Systems. It 

is available in one color: white enclosure, red optical indicator. 

Acoustic indication is based on a dynamic transducer. The sound intensity generated by signaling device 

is  120  dB  at  1  meter  distance.  Optical  indication  uses  modern  super-bright  LED  so  that  the  light  of  the 
signaling device is clearly visible. 

In  addition  to  the  basic  function  of  the  optical  and  acoustic  signal  generation  at  the  time  of  alarm,  the 

signaling  device  features  a  large  number  of  additional  functions such  as  alarm  memory,  Intrusion  Detection 
System status indication (i.e. arming, disarming) or change of sound modulation. There are several modes of 
siren  activation.  All  of  these  features  are  supported  by  the  microcontroller  of  the  device,  while  the 
programming is simple and intuitive. 

 
 

Содержание SR136

Страница 1: ...coustic indication is based on a dynamic transducer The sound intensity generated by signaling device is 120 dB at 1 meter distance Optical indication uses modern super bright LED so that the light of...

Страница 2: ...losure of the SR136 unscrew the screw in the bottom of the housing and bend the upper part of the enclosure lid upwards Caution When mounting keep an appropriate distance minimum 5 cm between the top...

Страница 3: ...device Power supply of the signaling device is supplied to the and terminals The signaling device can operate with or without the 12V 2 2Ah battery The battery should be connected to the BAT socket Ca...

Страница 4: ...ng the A control input input polarization ON Activating the function by giving a plus to the A terminal OFF Simultaneous launching of the speaker and lamp the S terminal DIP3 CMD Separation of optical...

Страница 5: ...several optical signals at the moment of disarmament DIP2 MEMORY LIGHT Optical alarm memory OFF Disabling the function ON Arming indicated by the signaling device with 3 short acoustic signals Disarm...

Страница 6: ...no alarm no acoustic indication opened from ground with S alarm acoustic indication shorted to ground with A no alarm no optical indication opened from ground with A alarm optical indication Caution...

Страница 7: ...ontrolling the OUT5 output shorting the output to ground which is connected via the 1k resistor it is possible to force the S input to a low state which results in activation of the signaling device 4...

Страница 8: ...to periodically test the signaling device The majority of Intrusion Detection Systems indicates malfunctioning of the signaling devices and informs the user with an appropriate message on the LCD keyp...

Страница 9: ...ience however not later that within 14 days from the delivery to the service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilitie...

Отзывы: