AMC SR 133 Скачать руководство пользователя страница 2

www.amcelettronica.com

installation instructions

SR 133

1. INTRODUCTION

ENGLISH

SR 133 is a high-power back-up battery siren (105 dB at 3m) protected against tampering (opening, tearing off). It 

features a 10W flasher and a sound/flash timer, variable with adjustable trimmer from 1 min. to 7 min., which trips in 

case of prolonged alarm (eg. connection cable cutting). It has a first switch-on stop function to prevent the siren from 

tripping during installation. (for enabling the siren for normal use it’s necessary  to activate/deactivate alarm start).

3. INSTALLATION

 configure jumpers J11, J12 and LAUNCHING according to siren starting mode.

connect the 12VDC 2Ah buffer battery to the red and black wires with faston (in case of “launching” starting mode, 

there is no battery);

connect external 13.8 VDC power supply to the SUPPLY terminals (*);

connect siren start line from the alarm panel to the START terminal (in case of “launching” starting mode, the START 

terminal must be connected to the +12V terminal);

the anti-opening/tearing contact must be connected to the relevant circuit of the alarm unit through the TAMPER 

contacts;

time the trimmer to desired sound and flash;

close the metal cover using the screws provided

close the siren by means of the plastic cover.

2.REGULATION AND CONTROL

Trimmer TR1 :  sound and flashing timer adjustment from 1’ to 7’ ± 20%
TAMPER terminals : contact N.C. resistant to opening and rip-off

SUPPLY terminals : 13.8 VDC power supply ( rated )
START terminal :

“positive missing” 

 

Jumper J11=    

 

open

    Jumper 

J12= 

 

  female 

jumper 

on 

B

    Jumper 

LAUNCHING 

 

female 

jumper 

on 

OFF

“negative missing” 

 

Jumper J11=    

 

closed

Jumper 

J12= 

 

  female 

jumper 

on 

A

    Jumper 

LAUNCHING 

 

female 

jumper 

on 

OFF

“Start with positive”   

 

Jumper J11= 

 

 

open

    Jumper 

J12= 

 

  female 

jumper 

on 

A

  

 

 

 

Jumper LAUNCHING 

=  

female jumper on OFF

Connect a 10Kohm resistor between terminal “START” and terminal “-12V”         

“Start with negative” 

 

Jumper J11=    

 

open

    Jumper 

J12= 

 

  female 

jumper 

on 

B

    Jumper 

LAUNCHING 

 

female 

jumper 

on 

OFF

Connect a 10Kohm resistor between terminal “START” and terminal “+12V”      

“launching”            

 

Jumper J11=    

 

open

Jumper 

J12= 

 

  female 

jumper 

on 

A

Jumper LAUNCHING 

=  

female jumper on ON

In the “launching” mode, the “+12v” terminal must be connected to the “start” terminal (no back-up battery)
IMPORTANT:  In the launching mode the siren starts howling as soon as power is supplied at the terminals 

“supply”. In this mode there is no first switch-on stop function.