www.amcelettronica.com
Installation Instructions v1.1
SMILE 19
Pir Detector
2
LENS
SMILE 19
permette una
copertura di 15 mt, la
speciale
conformazio-
ne della lente permette
un’apertura orizzontale
di oltre 90° con 29 fasci
su 5 livelli
SMILE 19
allows a ran-
ge of 15 mt, the special
lens shape provides a
horizontal coverage of
more than 90° with 29
patterns on 5 levels.
SMILE 19
Alimentazione / Input Voltage
9 to 15 Vcc
Consumo / Current Drain
(18 mA/9.5mA) @ 13.8 Vcc
Portata in lunghezza / Coverage
15 mt
Portata in larghezza / Angle
90°
Piroelettrico / PIR
2 elementi / 2 elements
Lente / Lens
29 patterns on 5 levels
Antiapertura / Anti-opening
✔
Antistrisciamento / Creep zone
✔
Contatto di allarme / Alarm contact
0.2 A - 24 Vcc
Contatto di tamper / Tamper switch
Max 40 mA - 30 Vcc
Temperatura di esercizio / Operating temperature
From -10 °C to +55 °C
RFI Protezione / Protection
30 V / m (20 MHz - 2000 MHz)
Led WALK TEST
✔
WALK TEST IN
✔
Cover / Housing / Boiter
ABS
Dimensioni / Dimensions
110 x 60 x 46 mm
SPECIFICATIONS
L’installazione deve essere eseguita a regola d’arte da personale specializzato.
Il produttore declina ogni responsabilità nel caso in cui il prodotto venga manomesso da persone non autorizzate.
Si raccomanda di verificare il corretto funzionamento del sistema d’allarme almeno una volta al mese, tuttavia un sistema di allarme elettronico
affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situazioni si verifichino.
Installation must be carried out following the local installation norms by qualified personnel.
The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.
It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and due to, but not limited to,
any or all of the following: tampering, electrical or communication disruption or improper use, it is possible for the product/system to fail to prevent
burglary, rubbery, fire or otherwise. A properly installed and maintained alarm system can only reduce the risk that this happens.
Meets the requirements: EN 50131-2-2 Grade 2 EN 50131-2-2 Class 2
JP1
= doubble pulse
JP2
= Walk test led
ALARM
= alarm contact
AP
= tamper contact
SUPPLY
= power supply 13.8Vcc
JP1
= doppio impulso
JP2
= Walk test led
ALARM
= contatto allarme
AP
= contatto tamper
SUPPLY
= alimetazione 13.8Vcc
VISTA IN PIANTA
VISTA LATERALE
Copertura minima
Copertura massima
0°
45°
45°