Installation Instructions v1.1

SMILE 19

 Pir Detector

2

LENS

SMILE  19

  permette  una 

copertura  di  15  mt,  la 

speciale 

conformazio-

ne  della  lente  permette 

un’apertura  orizzontale 

di  oltre  90°  con  29  fasci 

su 5 livelli

SMILE  19

  allows  a  ran-

ge  of  15  mt,  the  special 

lens  shape  provides  a 

horizontal  coverage    of  

more  than  90°    with  29 

patterns on 5 levels.

SMILE 19

Alimentazione / Input Voltage

9  to 15 Vcc

Consumo / Current Drain

(18 mA/9.5mA) @ 13.8 Vcc

Portata in lunghezza / Coverage

15 mt 

Portata in larghezza / Angle

90°

Piroelettrico / PIR 

2 elementi / 2 elements

Lente / Lens

29 patterns on 5 levels

Antiapertura / Anti-opening 

Antistrisciamento / Creep zone 

Contatto di allarme / Alarm contact 

0.2 A - 24 Vcc 

Contatto di tamper / Tamper switch 

Max 40 mA - 30 Vcc

Temperatura di esercizio / Operating temperature

From  -10 °C  to +55 °C 

RFI Protezione / Protection 

30 V / m (20 MHz - 2000 MHz)

Led WALK TEST

WALK TEST IN

Cover / Housing / Boiter

ABS

Dimensioni / Dimensions

110 x 60  x 46  mm

SPECIFICATIONS

L’installazione  deve essere eseguita a regola d’arte da personale specializzato.

Il produttore declina ogni responsabilità nel caso  in cui il prodotto venga manomesso da persone non autorizzate. 

Si raccomanda di verificare il corretto funzionamento  del sistema d’allarme almeno una volta al mese, tuttavia un sistema di allarme  elettronico  

affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situazioni si verifichino.

Installation must be carried out following the local installation norms by qualified personnel. 

The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.

It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and due to, but not limited to, 

any or all of the following: tampering,  electrical or communication disruption or improper use,  it is possible for the product/system to fail to prevent 

burglary, rubbery, fire or otherwise. A properly installed and maintained alarm system can only reduce the risk that this happens. 

Meets the requirements: EN 50131-2-2 Grade 2  EN 50131-2-2 Class 2

JP1

= doubble pulse

JP2 

= Walk test led

ALARM 

= alarm contact

AP 

= tamper contact

SUPPLY

 = power supply 13.8Vcc

JP1

= doppio impulso

JP2 

= Walk test led

ALARM 

= contatto allarme

AP 

= contatto tamper

SUPPLY

 = alimetazione 13.8Vcc

VISTA IN PIANTA

VISTA LATERALE

Copertura minima

Copertura massima

45°