AMC MMA 60 Скачать руководство пользователя страница 5

     

 

Welcome 

Congratulations  on  purchasing  MMA  series  multi-function  commercial  amplifier.  New  MMA  series  amplifiers  are 

designed  to  provide  a  big  impact  in  sound  reproduction  and  to  produce  highest  quality  audio  at  an  affordable 

price. We wish you great enjoyment and satisfaction when using your amplifiers, whether you are an installation, or 

reinforcement engineer. 

 

Unpacking and Installation 

Although installing and operating this amplifier is not complicated, a few minutes of your time is required to read 

this manual to install this device properly and become familiar with its features and how to use them. Please pay 

attention  to  given  precautions  when  using  or  moving  this  device.  Never  place  the  unit  near  radiator,  in  front  of 

heating  vents,  to  direct  sun  light.  It  should  not  be  used  in  excessive  humidity  or  dusty  environment.  Otherwise 

warranty may be voided. 

Connect this unit with matching system components described on the following pages. 

 

Features 

MMA 60, MMA 120 and MMA 240 are comprehensive, all-in-one mixer-amplifier solutions for commercial 

and industrial applications, providing all necessary features in a single unit. 

 

 

Six microphone or line inputs offering   

    XLR and RCA jacks, 

 

Adjustable input gain, 

 

Remote microphone via phoenix connector, 

 

M.O.H (Music On Hold) output, 

 

Telephone paging input via phoenix connector, 

 

Assignable phantom power for Channel 1 and   

    Channel 2, 

 

Three level priority muting, 

 

Built in four type user selectable pre-announce   

    chime, 

 

 

60 watts (MMA 60), 120 watts (MMA 120),   

    240 watts (MMA 240) rated power output, 

 

High efficiency Class-D Amplifier (MMA 240), 

 

Advanced protection system includes current limiting, 

over current and thermal protection, 

 

Seven band graphic equalizer, 

 

Expendable by adding audio mixer and power   

    amplifier with LINK and PRE-AMP terminal, 

 

Low distortion and low noise level, 

 

Compact size and lightweight. 

 

ldeal for commercial and industrial use. 

 

 

 

 

Содержание MMA 60

Страница 1: ......

Страница 2: ...rt Precautions 3 Before you start 5 Controls and connections Front panel 6 Rear panel 6 Installation Rack mounting 7 Wire connectors 8 Connections 10 Adjusting amplifier 14 Specifications Block diagra...

Страница 3: ...st damage nor modify the power supply cord In addition avoid using the power cord close to heaters and don t place heavy object including the amplifier itself on the power cord as it may cause fire or...

Страница 4: ...aterials into the ventilation slots of the amplifier for it may result fire or electric shock DO NOT open nor remove the amplifier cover to prevent fire or electric shock for there are high voltage co...

Страница 5: ...warranty may be voided Connect this unit with matching system components described on the following pages Features MMA 60 MMA 120 and MMA 240 are comprehensive all in one mixer amplifier solutions for...

Страница 6: ...nput channel volume controls 9 Power switch 5 Master volume controls Rear panel description 1 AC fuse 7 Signal input connectors 2 Expansion ports AMP IN PRE AMP OUT LINK IN LINK OUT 8 Remote microphon...

Страница 7: ...units for efficient convection cooling There should be also left 2 inches space between unit sides and rack side walls and 4 inches from unit rear panel and back of the rack How to attach rack mount b...

Страница 8: ...ment for appropriate wiring application RCA input connectors may also be used for unbalanced signal inputs Balanced line Balanced line Unbalanced line Unbalanced line TRS mono jack for unbalanced conn...

Страница 9: ...the appropriate size wire based on the distance between amplifier and speaker The wire sizes are given for a 4 load NOTE Custom wiring should only be performed by qualified personnel CAUTION Never use...

Страница 10: ...positive lead Impedance and output voltages ratios MMA 60 4 15 5V 10 25V 83 70V 165 100V MMA 120 4 22V 5 2 25V 42 70V 83 100V MMA 240 4 31V 2 6 25V 21 70V 42 100V NOTE The total speaker system impeda...

Страница 11: ...Possible speaker connection types are shown in a figure below CAUTION Never use both the Low Z 4 and Hi Z 25V 70V and 100V terminals at the same time...

Страница 12: ...Typical input and output wiring diagram is shown in a figure below...

Страница 13: ...desired sound output NOTE Inserting a 1 4 TRS jack into AMP IN terminal disconnects internal power amplifier section from the mixer section Expanding MMA series MMA series mixer amplifier allows expan...

Страница 14: ...changing jumper position on a T3 Priority This function allows talk over for MIC channel 1 and 2 While this function is activated all other input signals are muted Figure shows the priority switches a...

Страница 15: ...IN Channel 6 input channel Tele paging function Priority signal from PBX station could be connected to MMA series mixer amplifier via TELE PAGING Phoenix connector This way public announcement could...

Страница 16: ...Example application diagram is shown in a figure below...

Страница 17: ...Block diagram...

Страница 18: ...5Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz 12dB Signal to Noise Ratio at rated power output Better than 90dB Crosstalk at all control maximum 70dB at 1kHz Total Harmonic Distortion THD at 1kHz rated power Le...

Отзывы: