AMC MA 240 Скачать руководство пользователя страница 8

USER MANUAL     

MA 240

 Mixing ampliier

06

Operation

Rear panel operation 

VENTILATION HOLES

To ensure proper amplifiers cooling leave these ventilation’s holes unblocked. 
Blocked ventilation’s holes can be reason of amplifiers damage.

POWER CONNECTOR AND AC FUSE

Power connector is designed for main powers connecting to ampliier. This 
connector is combined with fuse holder and 6.3A 250V fuse inside.

+24V DC TERMINAL

24V DC terminal is designed to power up the ampliier when the main power 
is unavailable. Use only DC 24V power supply or batteries and take attention to 
polarity during the wiring. 24V DC Current - 20A.

OUTPUT TERMINAL

Output terminal is designed to connect audio line to amplifier. There are availa-

ble 4 types of output: low impedance 4 Ω output, 25 V, 70 V and 100 V outputs 
for audio line. Please ind some connection examples below in this user manual.

PREAMPLIFIER OUTPUT

This is line level output directly from device preampliier. Preampliier output 

and amplifier input are designed to insert signal processor such as equalizer or 
limiter.

INPUT TO POWER AMPLIFIER STAGE

This is line level input directly to device power ampliier. Preampliier output 

and amplifier input are designed to insert signal processor such as equalizer or 
limiter.

REC OUTPUT

This is line level stereo RCA output to connect audio recording equipment.

AUX INPUT

Line level stereo RCA input. AUX input allows to connect the line level audio, 
input level can be adjusted by using AUX knob, located in the front panel.

BALANCED XLR INPUTS

These balanced XLR inputs are universal, the gain (MIC or LINE) of these inputs 
are selectable by switch located near the input in the rear panel. If the 24V 
PHANTOM power is activated the input gain sets to microphone level automati

-

cally. Please note: Phantom power is switchable on each XLR input separately.
First balanced XLR input have a priority against other inputs.

Содержание MA 240

Страница 1: ...User Manual MA 240 Mixing ampliier...

Страница 2: ...he product 7 The power supply should be undamaged and never share an outlet or extension cord with other devices Never leave device plugged into the outlet when it is not being used for a long period...

Страница 3: ...240 Mixing ampliier Before you start Introduction 2 Features 2 Operation Front panel 3 Rear panel 4 Front panel operation 5 Rear panel operation 6 7 Output terminal 8 9 Controls and connectors Connec...

Страница 4: ...op bar or restaurant personnel can manage the installation of these mixing amplifiers by itself Can be used as a component of voice evacuation or public address system Line microphone inputs phantom p...

Страница 5: ...SER MANUAL MA 240 Mixing ampliier Front Panel 1 XLR inputs level control 2 AUX input level control 3 Tone control 4 Master volume 5 Output level indicator 6 Power switch 7 Power indicator Operation 03...

Страница 6: ...3 24V DC terminal 4 Output terminal 5 Preampliier output 6 Input to power amplifier stage 7 Stereo RCA REC output 8 Stereo RCA AUX input 9 Balanced XLR inputs 10 Music on hold level control 11 Connec...

Страница 7: ...ined when the knobs are set to middle position Turn bass control knob BASS and treble tone control knob TREBLE respectively clockwise to raise tone level by approximately 10 dB turn counterclockwise t...

Страница 8: ...this user manual PREAMPLIFIER OUTPUT This is line level output directly from device preampliier Preampliier output and amplifier input are designed to insert signal processor such as equalizer or lim...

Страница 9: ...be con trolled by level knob This knob is located near the TEL input connectors GAIN AND PHANTOM POWER SELECTOR This selector is designed to adjust the gain for the balanced XLR inputs and select 24V...

Страница 10: ...V DC24V 8 ohm 8 ohm Total impedance 4 ohm COM 4 25V 70V 100V DC24V 4 ohm 4 ohm Total impedance 8 ohm COM 4 25V 70V 100V DC24V 4 ohm Connecting the speakers to 4 ohm output COM 4 25V 70V 100V DC24V Con...

Страница 11: ...same time Operating amplifiers using 4 ohm and 70 or 100 volt concurrently may cause damage to the amplifier or connected speakers There is possibility to connect external power supply external batter...

Страница 12: ...Cable to balanced input from balanced output TRS connectors Cable to unbalanced input from balanced output TRS and TS connectors Cable to balanced input from unbalanced output TS and TRS connectors C...

Страница 13: ...d output TS and XLR connectors Cable to balanced input from balanced output TRS and XLR connectors RCA cable Cable to unbalanced input from RCA output RCA and TS connectors Cable to balanced input fro...

Страница 14: ...er supply AC 230V 50 Hz or 24V DC Fuses Fuse for AC power 6 3A 250V 5 2x20mm Output power 240 W AC power consumption 600 W Total harmonic distortions 1 Priority Input 1 Input sensitivity Line 8 dBu MI...

Отзывы: