AMC iM05 Скачать руководство пользователя страница 4

All the safety and operating instructions should be read
before the appliance is operated.

The safety and operating instructions should be retained for
future reference.

All warnings on the appliance and in the operating instructions
should be adhered to.

All operating and use instructions should be followed.

The appliance should not be used near water - for example,
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet
basement, or near a swimming pool, etc.

The appliance should be used only with a cart or stand that is
recommended by the manufacturer.

An appliance and cart combination should be

moved with care. Quick stops, excessive force,

and uneven surfaces may cause the appliance

and cart combination to overturn.

This equipment is not designed for use mounted on a wall or a
ceiling.

The appliance should be situated so that its location or position
does not interfere with its proper ventilation. For example, the
appliance should not be situated on a bed, sofa, rug, or similar
surface that may block the ventilation openings, or placed in a
built-in installation, such as bookcase or cabinet that may
impede the flow of air through the ventilation openings.

At least 30cm free space around the unit for normal ventilation is
required.

Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including amplifiers) that
produce heat.

The appliance should be connected to a power supply only of
the type described in the operating instructions or as marked
on the appliance.

Power-supply cords should be routed so that they are not likely
to be walked on or pinched by items placed upon or against
them, paying particular attention to cords at plugs,
convenience receptacles, and the point where they exit from
the appliance

Do not defeat the safety purpose of the polarized or grounding-
type plug. A polarized plug has two blades with one wider than
the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided
for your safety. When the provided plug does not fit into your
outlet. consult an electrician for replacement of the obsolete
outlet.

Unplug this apparatus during lightning storms or when unused
for long periods of time.

No object filled with liquids, such as vases, etc. shall be placed
on the apparatus.

Only use attachments/accessories specified by the
manufacturer.

The user should not attempt to service the appliance beyond
that described in the operating instructions. All other servicing
should be referred to qualified service personnel.

The appliance should be serviced by qualified service
personnel when:
a)

The power-supply cord or the plug has been damaged; or

b)

Objects have fallen, or liquid has been spilled into the
appliance; or

c)

The appliance has been exposed to rain; or

d)

The appliance does not appear to operate normally or
exhibits a marked change in performance; or

e)

The appliance has been dropped, or the enclosure is
damaged.

1. READ INSTRUCTIONS

2. RETAIN INSTRUCTIONS

3. HEED WARNINGS

4. FOLLOW INSTRUCTIONS

5. WATER AND MOISTURE

6. CARTS AND STANDS

6A.

7. WALL OR CEILING MOUNTING

8. VENTILATION

9. HEAT

11. POWER SOURCES

12. POWER CORD PROTECTION

13. POLARIZED PLUG

14. UNPLUG POWER CORD

15. OBJECT AND LIQUID ENTRY

16. ACCESSORIES

17. SERVICING

18. DAMAGE REQUIRING SERVICE

10. CLEANING

The appliance should be cleaned only with dry cloth.

IMPORTANT SAFETY INSTRUCTION

3

Содержание iM05

Страница 1: ...GUIDE Studio Architectural Balanced Unbalanced Monitor Speakers Multi zone Speakers with and input connectors for Monitoring and architectural for fitting up to 500ft CAT5 cable wiring systems like A...

Страница 2: ...ction 4 What s in the Box 4 iM05 Features 4 Front and Rear Panel Features 5 Installation 7 Connecting to Preamp or Computer Outputs 8 Placing the iM05 9 Appendix A Technical Specifications 10 Table of...

Страница 3: ...areil au fournisseur de pour le transformer Einige Ger te sind mit Umschaltern f r unterschiedliche Netzspannungern ausger stet Ein Vermerk auf der R ckseite weist darauf hin Die Anpassung wenn notwen...

Страница 4: ...on or pinched by items placed upon or against them paying particular attention to cords at plugs convenience receptacles and the point where they exit from the appliance Do not defeat the safety purp...

Страница 5: ...balanced low mid frequency response along with a defined mid and high frequency response as well Both drivers are magnetically shielded for desktop music production For pro engineers at commercial st...

Страница 6: ...me conditions The custom design on the front panel will aid in diffraction and will benefit stereo imaging The active crossover networks and power amplifiers for the iM05 are specially designed for th...

Страница 7: ...s can be done by wiring the ring and sleeve of the TRS plug together The TRS input is summed through a balanced input amplifier with the XLR input allowing both inputs to be used simultaneously Input...

Страница 8: ...ter or game console outputs We recommend that you use high quality balanced or unbalanced cables for input connections Also ALWAYS turn off the power of the iM05 and turn the volume of the iM05 down t...

Страница 9: ...sure that the power switch of the iM05 is turned off and that the volume control of the iM05 is turned down to a minimum Connect the male end of a TRS balanced or TS unbalanced cable to the TRS input...

Страница 10: ...regular triangle Refer to the following diagram 2 Position the monitors so that the top of the woofers are level with your ears in a normal listening environment Refer to the following diagram 3 Plac...

Страница 11: ...hout packing 56Hz 22kHz 3kHz 40W 30W 100dB typical A weighted 20k ohms balanced 10k ohms unbalanced 85mV pink noise input produces 90dBA output SPL at one meter with volume control at maximum RF inter...

Страница 12: ...Part No 21R 4212 www amchome com...