installation instructions

IF16T

www.amcelettronica.com

IF16T

FÜGGÖNY KARAKTERISZTIKÁJÚ MOZGÁSÉRZÉKELŐ

PIR CURTAIN LENS INTRUSION DETECTOR 

TELEPITŐ

INSTALLATION

1. INTRODUCTION

IF16T

 is a  curtain pir sensor, can create a barrier of protection useful for doors and windows.

And it is possible set a delay system activation.

2. DELAY SYSTEM ACTIVATION FUNCTION (DIP4 - DIP5)

Turning ON the DIP introduces a time delay between the instant of the sensor detects the move-

ments and the instant at which trigger the alarm relay. After the first violation, the sensor will count 

the set time, after this time and for more 10 sec. there will be some movement, turn in alarm, if after 

the set time there will be no movements, the sensor will go into reset. 

The sensor is designed to be installed to protect the openings, for example between the window 

and the shutter, or to doors and gates. Due to the high angle of coverage and the ability to rotate 

the lens on the support of the pyroelectric, you can install it in different ways, from top to bottom or 

on one side.

For the dip switch settings see the diagram below

3. INSTALLING AND SETTING

DIP-SWITCH

OFF

ON

DIP 1-6-7-8 not used

DIP 2

walk led OFF

walk led ON

DIP 3

2mt coverage

3.5mt coverage

DIP 4

immediate alarm

Delayed 30’’ + 10’’  (dip4 ON + dip5 ON = 1’30’’)

DIP 5

immediate alarm

Delayed 1’  (you can add the time at 1’30”with dip)

4. INSTALLATION AND CONNECTIONS

Choose a suitable location, mount the sensor using the turrets tear to get the tamper protection.

The cable can go from a tiny hole next to the terminals, or if the section is very large, you can switch 

from the knock-out (see figure below)

Fixed base rear slide the cable through the holes selected, secure the board in its housing interlo-

cking and fix the cables into the appropriate terminals.Fix with screw the top.

In the figure at the end of manual, you can see different types of installation, in the center of the 

window or on a side. The drawings are for guidance only, so you should always test the sensor.

5. WARM UP AND OPERATION

At start up the sensor needs a warm up time, this time is about 40’’. There will be fewer violations 

during this time is the faster entry into operational mode.

Operating without options:

 when the sensor is ready ,after the first violation, the waiting time for 

second violation is a few seconds (5 sec. max). 

Operation with delay times (dip 4 - 5): 

with the delay time set, you can access protected air wi-

thout giving alarm, so you can access the system without disarm. After this time, the sensor resets 

without giving alarm. If  after the set time for more 20seconds, the sensor detects movement still 

give alarm.