AMC IA series Скачать руководство пользователя страница 7

 

 
 
Wiring Guide 
 

We recommend using pre-built or professionally wired balanced line for input connector. 22 to 24 
gauge cables. 
Below picture shows connector pin assignments for wiring. 
 

 

1.

 

ground/shield 

2.

 

 hot  (+ve) 

3.

 

 cold (- ve) 

 
For unbalanced connection  
pin 1 and 3 have to be bridged 

For output connector we recommend using pre-built or professionally wired, high quality, and heavy 
gauge speaker wires. You may use Phoenix blocks for your output connectors. 
To prevent the possibility of short-circuits, wrap or insulate exposed loudspeaker cable connectors. 
Using the guidelines below, select the appropriate size wire based on the distance between amplifier 
and speaker. The wire sizes are given for a 4-ohm load. 
 

NOTE :

 Custom wiring should only be performed by qualified personnel. 

CAUTION : 

Never use shielded cable for output power wiring 

 
 
 

Distance 

Wire size 

Up to 25 ft.    (7,5 m) 

16 AWG (Ø 1,29mm) 

25 - 40 ft.       (7,5 - 12 m) 

14 AWG (Ø 1,62mm) 

40 - 60 ft.       (12 m - 18 m) 

12AWG  (Ø 2,05 mm) 

60 -100 ft.      (18 m - 30 m) 

10AWG  (Ø 2,5 mm) 

100 - 150 ft.   (30 m - 45 m) 

8AWG    (Ø 3,2 mm) 

150 - 200 ft    (45 m - 60m) 

6AWG    (Ø 4,11 mm) 

     4 Ohm Wire Guide 

 

OUTPUT : Maintain proper polarity on output connectors. 
For output channel, connect the output EURO block terminals to the loudspeaker loads. Use 
terminals marked (4Ω) for a 4-ohm loudspeaker load, or use terminals marked 70V or 100V and 
COM for constant-voltage loudspeaker loads. 
Connect the COM terminal to speaker negative(-) lead; connect one of the other terminals to 
speaker po) lead. 
 
 
 
 

 
 

   Impedance and output voltages

 

  
 
 
 

iA120 

4Ω / 22V 

41Ω / 70V 

83Ω / 100V 

iA240 

4Ω / 31V 

21Ω / 70V 

41Ω / 100V 

iA360 

4Ω / 38V 

13.6Ω / 70V 

27.8Ω / 100V 

Содержание IA series

Страница 1: ......

Страница 2: ...CONTENTS Before you start Precautions 3 Before you start 5 Controls and connections Front panel 6 Rear panel 6 Connections 7 Specifications Diagrams 9 Specifications 10...

Страница 3: ...amage nor modify the power supply cord In addition avoid using the power cord close to heaters and don t place heavy object including the amplifier itself on the power cord for it may cause fire or el...

Страница 4: ...aterials into the ventilation slots of the amplifier for it may result fire or electric shock DO NOT open nor remove the amplifier cover to prevent fire or electric shock for there are high voltage co...

Страница 5: ...oid damages and to guaranty a long reliable use Connect your unit with the system components according to the description on the following pages Features The iA120 iA240 and iA360 are comprehensive qu...

Страница 6: ...r with fuse holder Model Voltage 115 120 V AC 220 230 240 V AC iA120 T4AL 250V T 3 15AL 250 V iA240 T8AL 250V T4AL 250 V iA360 T12AL 250V T6 3AH 250 V 3 Speaker connection terminal 4 Ohm 70 V 100 V an...

Страница 7: ...ven for a 4 ohm load NOTE Custom wiring should only be performed by qualified personnel CAUTION Never use shielded cable for output power wiring Distance Wire size Up to 25 ft 7 5 m 16 AWG 1 29mm 25 4...

Страница 8: ...nce and output voltage table represents total speaker system impedances Possible speaker connections are shown above CAUTION Never use both the Low Z 4 ohms and Hi Z 70V and 100V terminals at the same...

Страница 9: ......

Страница 10: ...H D at 1 2 rated output 1kHz Less than 1 0 Output Voltage and Impedance 4 22V 4 31V 4 38V 41 70V 21 70V 13 6 70V 83 100V 41 100V 27 8 100V Constructions Cooling Fan Operating temperature humidity 0 to...

Отзывы: