Using the AVA 4001 module in DASYLab® 16 

After running properly configured DASYLab® software the analog inputs will 
be available to the user. The inputs are listed in the following tab: Modules > 
Inputs/Outputs > MCC-DRV. The in AVA 4001 module only 4 analog inputs are 
available, while remaining 4 analog inputs, the outputs and the counters are not 
available. 

To use an analog input, just drag it inside the worksheet (or you may double-
click  it  and  indicate  the  module’s  position  on  the  worksheet).  A  window  will 
appear as shown in the figure below. Mark All Channel 0..7 and confirm your 
choice by clicking the OK button.  

 The user can configure the number of active 
analog inputs, measurement range separately for each channel as well 
as the sampling frequency. 

Double-clicking the analog input window on the worksheet opens the 
window shown below. This window needs to be discussed in detail, as 
it gives the user the option to configure the AVA module parameters 
for operation in DASYLab. The following areas can be distinguished: 

 

1.

 

You can enter your own module name in the Module name 
field and provide a short description in the Description field. 

2.

 

It  is  possible  to  activate  analog  inputs  in  this  area.  The 
symbol  with  disconnected  blue  sockets  stands  for  an 
inactive input. A double-click on the symbol activates the 
corresponding input and switches the symbol to connected 
sockets with a lightning. 

A single click on the active input changes its color from red 
to green. The changes of settings, which are explained in the 
following points, refer to the input marked in this way. 

The next figure presents a situation, in which four input channels are active, while the first is marked 
for editing settings. 

 

If necessary, an input can be deactivated by double right-clicking the icon of the active input. 

 

Attention 

In AVA 4001 module, inputs 4 - 7 are not used. Activating them will reduce the maximum available 
sampling frequency. 

 

Содержание AV ACQUISITION 4001

Страница 1: ...MC VIBRO Sp z amc VIBRO Sp z o o ul Pilotow 2e 31 462 Krakow Poland T 48 12 362 97 60 S 48 12 362 97 63 info amcvibro pl KRS No 0000618618 REGON No 364497010 VAT No PL6772403385 www amcvibro pl 4 CHAN...

Страница 2: ...3 3 Technical data 4 4 Measurement accuracy 5 5 Description of connections and status lights 7 6 Connection with a computer using Windows 7 7 7 InstaCal 8 8 DASYLab 16 configuration 8 9 Using the AVA...

Страница 3: ...to 100 kS s The provided drivers allow operation with DASYLab LabVIEWTM and Matlab Module characteristics operation with four IEPE standard vibration sensors sensor circuit functional check warnings...

Страница 4: ...channels is max 400 kS s Measurement range 10V 5V 2V i 1V selected by software Crosstalk 80 dB within 0 25 kHz band Maximum absolute error range 10V 5 66 mV range 5V 2 98 mV range 2V 1 31 mV Range 1V...

Страница 5: ...bly small and may be overlooked The device is equipped with a 16 bit ADC converter which transforms analog signals into values ranging from 0 to 65525 The following is an ideal characteristic for a 10...

Страница 6: ...elated to the difference between the slope of the real characteristics and the ideal characteristics and is expressed as a percentage For the 10 V range the gain error is 0 04 Adding the offset and th...

Страница 7: ...es not require the installation of any drivers in the operating system The operating system detects a new device automatically when connected and displays it in the hardware manager as a USB HID inter...

Страница 8: ...AVA module is connected to the computer A window will appear with a list of measurement cards which have been detected Mark the item named USB 1608FS click OK and close InstaCal The above procedure sh...

Страница 9: ...w This window needs to be discussed in detail as it gives the user the option to configure the AVA module parameters for operation in DASYLab The following areas can be distinguished 1 You can enter y...

Страница 10: ...this window in the Scan rate field it is possible enter required sampling frequency select the proper unit and in the Block size field it is possible to select proper size of data buffer Attention The...

Страница 11: ...lds as required The numbers should be equal in the absolute value When different values are entered for example 1V and 2V the program will signal an error and will suggest that the greater of them for...

Отзывы: