1

Important

Read these instructions before use.

This appliance must be installed in accordance with such 
regulations as are in force.

This appliance is for indoor use only.

Subject to compliance to clearance distances ventilation and flue 
requirements detailed in these instructions the heater can be used
inside marquees.

Only use in a well ventilated area.  See technical details Section 2.

The heater is not for domestic use.

The heater is designed for space heating only.

Do not use the heater in basements or below ground level.

This appliance is fitted with a hose and regulator.  

These instructions must be given to the user.

Suitable gloves should be worn when handling this equipment.

Observe the cool down period and never handle the heater when
hot.

Never place any objects, particularly combustible materials on top
of the heater and always ensure that flues are not obstructed.

Bend knees when lifting the product via the handles for wheeling.

Gas leaks

Propane gas is highly flammable and heavier than air.
Consequently in the event of a gas leak there is a risk of explosion.

Prior to use, check gas supply connections with leak detection
solution.  Never use a naked flame when checking for a gas leak.
In the event that bubbles are noted either rectify if 
considered competent or consult your supplier.

Do not use the heater until the fault is rectified.

In the event of a gas leak evacuate people from the immediate
area and open doors and windows.

Do not operate electrical switches.

If a lot of gas has escaped call the Fire Service.

After ventilating the room turn off the gas valve, and disconnect
the electrical connector to the heater.

If the appliance is hot leave to cool then with the aid of a 
competent person identify and rectify the source of the leak.

Gas cylinders

This heater is designed to be used with 47kg propane bottles.

Gas cylinders are heavy, never attempt to lift a cylinder, full or
empty, by yourself.  Always get help.

Keep cylinders upright at all times during use, transporting and
when stored.

Liquid gas can cause severe freeze burns so avoid skin contact by
wearing gloves when making connections or handling the 
cylinder.  If ice is noted on the cylinder ensure that cylinder is not
leaking.  If leaking is suspected do not use the cylinder.

Do not drop or knock a gas cylinder in that damaged cylinders can
be dangerous.

Do not store full or empty bottles in the operating area of the
heater and never apply heat to the cylinder.

Electrical supply

The heater is suitable for use with either a 230V/50Hz or
110V/50Hz supply.  A selector switch enables the user to choose
the desired voltage.  See section 3 step 4.

Only female electrical connectors compatible to the male 
connectors on the rear of the unit must be used.  

Always switch off and unplug the equipment when not in use.

Countries of destination 

GB, IE, BE, CH, FR, NL, ES & PT.

Model

Heat input gas

kW

51

45

Gas type

Propane G31

Gas category

I

3p(37)

I

3p(30)

Supply press

mbar

37

30

Injector size

4.6

4.6

Electrical supply

110V

Electrical input

400W

Weight

85kg

Hose

1.5m lg, 8mm ID approved to 

EN 1763-1 BS3212 (UK Only)

Regulator

4kg/h

4kg/h

37mbar

30mbar

Min Room size

510m

3

Required 
ventilation

1275cm

2

1  Health & safety details

2  Technical details

Содержание Tornado 600

Страница 1: ...Operation maintenance and servicing manual Wolfe Design Ltd MOBILE RADIANT HEATERS ...

Страница 2: ...h safety details Technical details Moving the product Operating instructions Cleaning maintenance Servicing instructions Fault finding Ducted options Spare parts 3 2 1 4 5 6 7 8 9 MOBILE RADIANT HEATER Index ...

Страница 3: ...escaped call the Fire Service After ventilating the room turn off the gas valve and disconnect the electrical connector to the heater If the appliance is hot leave to cool then with the aid of a competent person identify and rectify the source of the leak Gas cylinders This heater is designed to be used with 47kg propane bottles Gas cylinders are heavy never attempt to lift a cylinder full or empt...

Страница 4: ...0 volt electrical supply by inserting a suitable connector lead into either the 110 or 230 volt appliance connectors Attach the regulator to the gas bottle using the spanner provided Note Left hand thread Ensure the hose is not twisted or damaged and that the gas bottle is positioned at the side of the unit to avoid heating at the outlet Note When positioning the heater please ensure that all inle...

Страница 5: ...rical mains and gas cylinder When heating is complete turn OFF the gas supply Leave the electric supply turned ON to enable the combustion fan to operate for 10 minutes to cool the product prior to moving After cooling is complete switch the 3 position rocker switch Step 7 on the rear of the product to the OFF position and disconnect from the electric supply and remove the electrical connector Dis...

Страница 6: ...and flue outlet on the sides of the product are clean and free from any blockage The casing can be cleaned with a soft cloth and a mild detergent as required 5 Cleaning maintenance 6 Servicing instructions Step 1 Place the product on the rear ring in the vertical position to gain access to the fan cover Step 2 Remove the fan access cover Remove the four bolts that attach the fan to the base of the...

Страница 7: ...s fixing the rear spinning to the case assembly and the gas hose Step 2 Remove the bolts securing the rear support to the case assembly Step 2 Heat exchanger assembly maintenance Remove the screws fastening the front spinning to case assembly Using a soft brush remove any dust and dirt from the rigid tubes flexible coil and reflector gaining access front and rear of the product Inspect the tube as...

Страница 8: ...trode assembly condition taking care when reassembling to ensure that the leads to the assembly are fitted the same way as on removal If the electrode assembly is in good order check the spark electrode gap This should be 3 5mm 0 5mm Adjust the gap if necessary by bending the earth rod Step 6 With a soft brush remove dust from the burner head filter If a blockage is suspected replace the filter by...

Страница 9: ...ector carrier and fulham hose nozzle from the gas valve The valve can be replaced and the injector carrier and fulham hose nozzle re fitted using an approved pipe joining compound on the threads of both components Carry out commissioning The governor should be fully screwed in i e put out of action To replace the electronic sequence controller transformer thermostat and pressure switch To remove t...

Страница 10: ...8 Figure 1 Vacuum switch connections Figure 2 Wiring diagram MOBILE RADIANT HEATER ...

Страница 11: ...s valve burner indicator light or associated wiring Burner proceeds to ignition stage normally No spark Check electrode for cracks replace if necessary indicated by audible spark valve energised Check high tension connections are secure and burner on light illuminated but burner Check spark gap is 3 5 0 5mm If no high tension does not light output from electronic controller replace controller Gas ...

Страница 12: ...e flue outlet to the axial fan air stream Secondly attach the rear flue pipe section at the end of the front section as shown above The securing clip can now be tightened to keep both section together In environments where dust moisture or fumes are present a ducted air inlet is provided to allow fresh air to be drawn into the burner to aid combustion and prevent obstruction of the burner mesh wit...

Страница 13: ...70 S FAS STA 125 S TOR 600 480 S TOR 600 530 S TOR 600 410 S TOR 600 510 S TOR 600 500 S TOR 600 450 S TOR 600 430 Description Part Number Igniter assembly Burner head mesh Jet carrier Combustion fan Transformer Axial fan c w basket Inlet spinning assembly Outlet spinning assembly Propane regulator Fulham hoze nozzle 3 8 BSPT x 10mm o d Gas hose S TOR 600 420 S ELE TRA 010 S TOR 600 570 S TOR 600 ...

Страница 14: ...e position 110 OFF 230volt switch Wheel Rear ring assembly Handle assembly black Controls hinge cover label S TOR 600 630 S TOR 600 300 S TOR 600 560 S TOR WHE 010 S TOR 600 620 S TOR 600 610 S TOR 600 600 S TOR 600 590 S TOR 600 580 S CLI HOS 010 S TOR 600 440 Description Part Number Harness BCH mini Overheat thermostat Capacitor Spanner S TOR 600 670 S TOR 600 640 S TOR 600 460 S TOR 600 520 9 S...

Страница 15: ... Facsimile 44 0 1384 489707 Website www ambirad co uk Model Ref HEA TOR PRO 600 For Sales and Service Contact Wolfe Designs Ltd 125 Clydesdale Place Moss Side Industrial Estate Leyland Lancs PR26 7QS Telephone 44 0 1772 456191 Facsimile 44 0 1772 622464 Website www wolfedesigns co uk BCEMA MOBILE RADIANT HEATER UK Patent Applicaion No 0226006 5 ...

Отзывы: