USER INFORMATION
14
With the control knob at the highest setting, rotate in a clock-wise
direction towards the lower setting as required.
The appliance is now operating at lower operating output.
Extinguishing the appliance back to permanent pilot
setting
From any heat setting, turn the
Control knob in a clockwise
direction to the “Pilot” position.
Extinguishing the appliance fully
From any heat setting, turn to
“Pilot” as in “Extinguishing the
appliance back to permanent pilot
setting”.
Depress the control knob slightly
and turn clockwise to “Off” position.
In the extent of a flue blockage or spillage, the monitoring system will
operate and turn off the fire. If this occurs extinguish the appliance
fully and re-light following the procedures as previously described.
If the fire repeatedly shuts down by the monitoring system, then a
specialist engineer should be informed.
INSTALLER INFORMATION
19
Testing and Commissioning
Turn on and test the gas supply up to the fire for any leaks, in
accordance with current edition of BS6891.
Test the setting pressures as detailed on page **.
Perform a spillage test as detailed on page **.
When the appliance is first used, the coating of various parts may
cure. It is advisable to ventilate the room during this period for at
least one hour.